首页> 外文期刊>Hong Kong journal of emergency medicine. >Hydrothorax Due to Extravasation of Intravenous Contrast after Power Injection through Right Subclavian Catheter
【24h】

Hydrothorax Due to Extravasation of Intravenous Contrast after Power Injection through Right Subclavian Catheter

机译:通过右锁骨下导管注入动力后静脉造影剂渗出引起的胸膜积水

获取原文
           

摘要

We report a case of hydrothorax after receiving intravenous (IV) contrast material by power injector through right subclavian central venous catheter (CVC) line. A 38-year-old woman presented to the local emergency department with hypotension after a pedestrian accident. After resuscitation, CVC was inserted into her right subclavian vein and fluid was administered well before computed tomography (CT) enhancement. Contrast-enhanced CT scan showed a large amount of extravasation of contrast material and fluid collection in the thoracic and pericardial cavities which was not shown in non-enhanced CT scan. During operation, vascular perforation was found in right subclavian vein. This case highlights that emergency physicians must keep in mind the possibility of vessel injury after CVC insertion and contrast material is preferably injected via peripheral IV access.
机译:我们报告通过右锁骨下中央静脉导管(CVC)线通过动力注射器接受静脉(IV)对比材料后的胸腔积液。一名38岁的妇女在发生行人交通事故后向当地急诊科降血压。复苏后,将CVC插入右锁骨下静脉,并在增强计算机断层扫描(CT)之前充分输注液体。对比增强的CT扫描显示胸腔和心包腔中大量的对比物质渗出和积液,未增强的CT扫描未显示。手术期间,在右锁骨下静脉发现了血管穿孔。这种情况表明,急诊医师必须牢记在插入CVC后血管损伤的可能性,并且最好通过周围的静脉通路注射造影剂。