This investigation was conducted to examine the probable cause of failure of one pendent reheater tube of a 110 MW thermal power plant. Preliminary macroscopic examinations along with visual examination, dimensional measurement, chemical analysis, evaluation of mechanical properties, oxide scale thickness measurement were carried out to predict the probable cause/causes of failure. In addition, optical microscopy was a necessary supplement to understand the reason for the failure. It was concluded that due to progressive erosion caused by the high velocity flue gas streams on the fire side wall, the tube had thinned down and could not cope the prevailing working stress. As a result, the affected areas of the tube suffered plastic deformation. Apart from that, formation of micro creep cavities due to rise in tube metal temperature (on the steam side) at localized places led to initiation of minor cracks before culminating to final rupture. The final failure is due to both these mechanisms occurring simultaneously.
机译:进行了这项研究,以检查110 MW火力发电厂一个悬挂式再热器管发生故障的可能原因。进行了初步的宏观检查以及外观检查,尺寸测量,化学分析,机械性能评估,氧化皮厚度测量,以预测可能的故障原因。此外,光学显微镜是了解故障原因的必要补充。结论是,由于火焰侧壁上的高速烟道气流引起的渐进腐蚀,管子变薄了,无法应付主要的工作应力。结果,管子的受影响区域发生塑性变形。除此之外,由于局部位置管金属温度升高(在蒸汽侧)而形成的微小蠕变腔导致微小裂纹的产生,最终达到最终破裂。最终的失败是由于这两种机制同时发生。