The cause of the failure of high temperature reheater tube of T23 Steel in 600MW supercritical unit of a power plant was analysed by visual examination, chemical analysis, microstructural examination, and mechanical property test (at room temperature). The results showed that the cause of reheater tube failure was a long-term overheating over 570 °C (in the furnace), which led to its mechanical properties to decrease, resulting in the tube burst with the longitudinal crack ruptures.
机译:通过视觉检查,化学分析,微观结构检查和机械性能检测(在室温下)分析了电厂600MW超临界单位的T23钢高温再热侵蚀管的原因。结果表明,再热管破坏的原因在570℃(炉中)的长期过热,这导致其机械性能降低,导致管突发与纵向裂纹破裂。