首页> 外文期刊>Haematologica >Quantification of D-dimer using a new fully automated assay: its application for the diagnosis of deep vein thrombosis | Haematologica
【24h】

Quantification of D-dimer using a new fully automated assay: its application for the diagnosis of deep vein thrombosis | Haematologica

机译:使用新型全自动测定法对D-二聚体进行定量:其在深静脉血栓形成诊断中的应用|血液学

获取原文
           

摘要

BACKGROUND AND OBJECTIVE: A D-dimer assay can be helpful to rule out thromboembolism provided it is sensitive, reliable, fast and easy to perform. Tests based on the ELISA methodology have a high diagnostic sensitivity, and are therefore adequate for excluding deep venous thrombosis (DVT). The drawbacks are their long assay times, unsuitability to be run on single samples and cost. New methods have been developed, based either on the same principle, by immunofiltration or by microlatex immunoturbidimetric assays which seem to reach the high sensitivity and negative predictive value (NPV) required, but allowing fast and quantitative single sample analysis. The aim of this work was to evaluate one rapid test, a fully automated quantitative assay (IL Test D-dimer, run on an ACL 7000 coagulation analyzer, Instrumentation Laboratory). DESIGN AND METHODS: We compared the diagnostic value of IL Test for DVT with that of an ELISA (Dimertest Gold EIA Agen Biomedical Limited, Acacia Ridge, Australia). Eighty-six patients (43 men, 43 women, mean age: 61 years) showing DVT symptoms formed the population for this non-randomized controlled trial in a referral center. The diagnosis of DVT based on the clinical history, was confirmed by serial compression ultrasonography (CUS) with Doppler flow in 62 patients. RESULTS: The IL Test D-dimer proved to be rapid, automated and well suited for individual tests with a good reproducibility in three control plasmas with different concentrations of D-dimer (coefficient of variation range 0.54-3. 87%). Its performance was comparable to that of the Dimertest Gold EIA, as indicated by the areas under the receiver operating characteristic curves (Dimertest Gold EIA 0.748; IL Test D-dimer 0.70). On the basis of kappa coefficients, there was a good concordance between the Dimertest Gold EIA and IL Test D-dimer when the receiver operating characteristic (ROC) curves suggested cut-offs were used. The sensitivity (98.3%) and NPV (88.9%) shown by IL Test D-dimer are comparable or even better than those obtained for EIA (95%, 80%, respectively). INTERPRETATION AND CONCLUSIONS: This study shows that the new method can be included in prospective clinical trials to test the utility of D-dimer measurement in combination with other non-invasive diagnostic procedures in the management of DVT diagnosis.
机译:背景与目的:D-二聚体测定法灵敏,可靠,快速且易于实施,有助于排除血栓栓塞。基于ELISA方法的测试具有较高的诊断敏感性,因此足以排除深静脉血栓形成(DVT)。缺点是测定时间长,不适合在单个样品上运行以及成本高。基于相同的原理,已经通过免疫过滤或微乳胶免疫比浊测定法开发了新方法,这些方法似乎达到了所需的高灵敏度和阴性预测值(NPV),但可进行快速定量的单样品分析。这项工作的目的是评估一项快速测试,一种全自动定量测定(IL Test D-二聚体,在ACL 7000凝血分析仪,仪器实验室上运行)。设计与方法:我们将IL Test对DVT的诊断价值与ELISA(Dimertest Gold EIA Agen Biomedical Limited,Acacia Ridge,澳大利亚)的诊断价值进行了比较。在转诊中心进行这项非随机对照试验的人群中,有86位患者(43位男性,43位女性,平均年龄:61岁)表现出DVT症状。 DVT的诊断基于临床病史,通过多普勒血流连续加压超声检查(CUS)证实了62例患者。结果:IL测试D-二聚体被证明是快速,自动化的,并且非常适合于单个测试,并且在具有不同浓度的D-二聚体的三个对照血浆中具有良好的重现性(变异系数范围为0.54-3。87%)。如接收器工作特性曲线下的面积所示,其性能与Dimertest Gold EIA相当(Dimertest Gold EIA 0.748; IL测试D-二聚体0.70)。根据kappa系数,当使用接收器工作特性(ROC)曲线建议使用截止值时,Domertest Gold EIA和IL测试D-二聚体之间存在良好的一致性。 IL测试D-二聚体显示的灵敏度(98.3%)和NPV(88.9%)与通过EIA获得的灵敏度(分别为95%,80%)相当或更好。解释和结论:这项研究表明,该新方法可用于前瞻性临床试验中,以测试D-二聚体测量与其他无创诊断程序相结合在DVT诊断管理中的效用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号