Background The assessment of hemodynamic status is a crucial task in the initial evaluation of trauma patients. However, blood pressure and heart rate are often misleading, as multiple variables may impact these conventional parameters. More reliable methods such as pulmonary artery thermodilution for cardiac output measuring would be necessary, but its applicability in the Emergency Department is questionable due to their invasive nature. Non-invasive cardiac output monitoring devices may be a feasible alternative. Methods A systematic literature review was conducted. Only studies that explicitly investigated non-invasive hemodynamic monitoring devices in trauma patients were considered. Results A total of 7 studies were identified as suitable and were included into this review. These studies evaluated in a total of 1,197 trauma patients the accuracy of non-invasive hemodynamic monitoring devices by comparing measurements to pulmonary artery thermodilution, which is the gold standard for cardiac output measuring. The correlation coefficients r between the two methods ranged from 0.79 to 0.92. Bias and precision analysis ranged from -0.02 +/- 0.78 l/min/m2 to -0.14 +/- 0.73 l/min/m2. Additionally, data on practicality, limitations and clinical impact of the devices were collected. Conclusion The accuracy of non-invasive cardiac output monitoring devices in trauma patients is broadly satisfactory. As the devices can be applied very early in the shock room or even preclinically, hemodynamic shock may be recognized much earlier and therapeutic interventions could be applied more rapidly and more adequately. The devices can be used in the daily routine of a busy ED, as they are non-invasive and easy to master.
机译:背景血液动力学状态的评估是对创伤患者进行初步评估的关键任务。但是,血压和心率通常会产生误导,因为多个变量可能会影响这些常规参数。需要更可靠的方法,例如用于心输出量测量的肺动脉热稀释法,但由于其侵入性,其在急诊科中的适用性值得怀疑。非侵入性心输出量监测设备可能是可行的选择。方法进行系统的文献综述。仅考虑明确研究创伤患者中非侵入性血液动力学监测装置的研究。结果总共7项研究被确定为合适,并纳入本评价。这些研究通过将测量值与肺动脉热稀释法(心输出量测量的金标准)进行比较,评估了总共1,197名创伤患者的无创血流动力学监测设备的准确性。两种方法之间的相关系数r在0.79到0.92之间。偏差和精度分析的范围从-0.02 +/- 0.78 l / min / m 2 到-0.14 +/- 0.73 l / min / m 2 。此外,还收集了有关设备的实用性,局限性和临床影响的数据。结论创伤患者无创心输出量监测装置的准确性令人满意。由于该设备可以很早地应用于休克室,甚至可以在临床前使用,因此可以更早地识别出血流动力学性休克,并且可以更快,更充分地应用治疗手段。该设备无创且易于掌握,可在繁忙的ED的日常工作中使用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号