首页> 外文期刊>Vojnosanitetski Pregled >Free-end saddle length influence on stress level in unilateral complex partial denture abutment teeth and retention elements
【24h】

Free-end saddle length influence on stress level in unilateral complex partial denture abutment teeth and retention elements

机译:自由端鞍长度对单侧复杂局部义齿基台牙和固位元件应力水平的影响

获取原文
           

摘要

Background/Aim. Different types of dental restorations are used for the therapy of unilateral free-end saddle edentulism. Unilateral complex partial denture is one of the indications for the Kennedy class II partial edentulism. The abscence of major connector and denture plate is an advantage compared to the conventional restorations, because of better comfort and shorter period of adaptation. The aim of the study was to analyse the influence of free-end saddle length change on the behaviour of unilateral complex partial denture supporting structures. Methods. Stress levels of the canine and the first premolar as retentional teeth and the attachments were tested under the influence of physiological forces with the loading point shifting distally in relation to the saddle length change. A virtual real size 3D model of the fixed part of the restoration (the canine and the first premolar with milled crowns) was created using the CATIA computer program. It was connected to the mobile part of partial denture with the SD snap in latch attachment. Mobile part of the restoration was designed in the region of 2, 3 and 4 lateral teeth (second premolar, first, second and third molar). By using the finite element method (FEM) stress levels analysis was performed under the load of physiological forces of 150 N in the free-end saddle teeth zone. Results. The results of analysis show that physiological forces cause a different stress distribution on the abutment teeth and the attachment, depending on the saddle length. Conclusion. The stress level values obtained for the abutment teeth as well as the attachment are far lower than the marginal ones. The behaviour of the system changes under this defined stress, but no plastic deformation occurs.
机译:背景/目标。不同类型的牙齿修复体用于治疗单侧自由端鞍状缺牙症。单侧复杂局部义齿是肯尼迪II类局部缺牙症的适应症之一。与传统的修复体相比,主要连接器和假牙板的缺席是一个优势,因为它具有更好的舒适性和更短的适应时间。该研究的目的是分析自由端鞍长度变化对单侧复杂局部义齿支撑结构行为的影响。方法。在生理力的影响下测试犬和第一前磨牙的应力水平,作为固定牙和附件,其载荷点相对于鞍座长度变化向远侧移动。使用CATIA计算机程序创建了修复体固定部分(犬齿和带有磨牙冠的第一个前磨牙)的虚拟真实尺寸3D模型。它通过闩锁附件中的SD卡扣连接到局部义齿的活动部分。修复体的活动部分设计在2个,3个和4个侧向牙区域(第二磨牙,第一磨牙,第二磨牙和第三磨牙)。通过使用有限元方法(FEM),在自由端鞍齿区域中在150 N的生理力负载下进行了应力水平分析。结果。分析结果表明,根据鞍座长度,生理力会在基台牙齿和附件上引起不同的应力分布。结论。从基牙和附件获得的应力水平值远低于边缘齿。在此定义的应力下,系统的行为会发生变化,但不会发生塑性变形。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号