This paper presents an improved average model and evaluation of an 18-pulse autotransformer rectifier unit (ATRU) in differential delta configuration. Average models remove the switching behavior of diode rectifiers and high bandwidth transients, which not only facilitates simulation of power systems by reducing computational cost but also enables impedance-based stability analysis for large complex power systems. To experimentally validate the proposed average model, a 2-kW, 18-pulse ATRU has been tested and the results of the derived model are compared with those of the switching model and experimental prototype. Computed transfer function of load impedance from the proposed average model closely resembles those of the switching model and the experimentally measured results validate the modeling procedure. Furthermore, stability analysis of the 18-pulse ATRU may be executed based on the return ratio of source and load impedance.
机译:本文提出了一种改进的平均模型,并对差动三角形配置的18脉冲自耦变压器整流器(ATRU)进行了评估。平均模型消除了二极管整流器的开关行为和高带宽瞬变,这不仅通过降低计算成本促进了电源系统的仿真,而且还可以对大型复杂电源系统进行基于阻抗的稳定性分析。为了通过实验验证所提出的平均模型,已对2kW,18脉冲ATRU进行了测试,并将衍生模型的结果与开关模型和实验原型的结果进行了比较。所提出的平均模型计算出的负载阻抗传递函数与开关模型的传递函数极为相似,实验测量结果验证了建模过程。此外,可以基于源极和负载阻抗的返回比来执行18脉冲ATRU的稳定性分析。