Suez-ResourceCo in Adelaide is a Construction & Demolition and Commercial & Industrial waste processing facility that produces alternative fuel for the local cement kiln operation. In recent years, Australia has seen an increase in energy cost and the state of South Australia has experienced a significant rise: approximately 29% increase in wholesale electricity price (2015/16 to 2016/17). Although the facility has been monitoring energy consumption at the gate level, the highly variable profile and many assets in operation have motivated the facility to conduct an energy flow analysis. The study identifies key assets for sub-metering to understand their energy profile and validate overall energy flow of the facility. The result outlines how the design paradigm of the waste industry has led to vastly over-sized plant leading to low efficiencies and power factors. Hence, potential energy and GHG saving is quantified through proposed efficiency gains.
机译:位于阿德莱德的Suez-ResourceCo是一家建筑与拆除以及商业和工业废物处理设施,可为当地的水泥窑生产替代燃料。近年来,澳大利亚的能源成本有所上升,南澳大利亚州也经历了大幅上涨:批发电价上涨了约29%(2015/16至2016/17)。尽管该设施一直在监控登机口的能耗,但是高度可变的配置文件和许多运行中的资产促使该设施进行了能量流分析。该研究确定了用于子计量的关键资产,以了解其能源状况并验证设施的总体能源流。结果概述了废物行业的设计范例如何导致工厂规模过大,从而导致效率和功率因数降低。因此,通过提议的效率提高来量化潜在的能源和温室气体节省。