首页> 外文期刊>Thermal science >Comparative performance analysis of experimental frigorific air conditioning system using R-134a and HFO-1234yf as a refrigerant
【24h】

Comparative performance analysis of experimental frigorific air conditioning system using R-134a and HFO-1234yf as a refrigerant

机译:使用R-134a和HFO-1234yf作为制冷剂的实验性冷冻空调系统的比较性能分析

获取原文
获取外文期刊封面目录资料

摘要

In this study, to evaluate the comparative experimental performances, a frigorific air conditioning system using HFO1234yf and R134a was developed and refrigerated air was introduced into a conditioned room. The experiment was carried out at different condenser inlet temperatures and using the refrigerants at different charges, 1250 g, 1500g, and 1750g. Experiments were conducted for a standard frigorific air conditioning system using the HFO1234yf and R-134a system. Air flow was introduced to the conditioned room for 60 minutes for each performance test. The results revealed that the temperature gradient in time was comparable for both refrigerants. The results of this investigation propose utilising HFO1234yf as a replacement for the currently favoured R134a in a frigorific air conditioning system.
机译:在这项研究中,为了评估比较实验性能,开发了一种使用HFO1234yf和R134a的制冷空调系统,并将冷冻空气引入到了空调室内。该实验是在不同的冷凝器入口温度下进行的,并使用了1250 g,1500 g和1750 g不同充注量的制冷剂。针对使用HFO1234yf和R-134a系统的标准冷冻空调系统进行了实验。对于每个性能测试,将空气流引入调节室60分钟。结果表明,两种制冷剂的时间温度梯度相当。这项研究的结果建议在制冷空调系统中使用HFO1234yf替代目前偏爱的R134a。