...
首页> 外文期刊>The Open Dentistry Journal >Evaluation of the Effect of Light and Scanning Time Delay on The Image Quality of Intra Oral Photostimulable Phosphor Plates
【24h】

Evaluation of the Effect of Light and Scanning Time Delay on The Image Quality of Intra Oral Photostimulable Phosphor Plates

机译:评估光和扫描时间延迟对口腔内光刺激性荧光板图像质量的影响

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Background:Nowadays, digital radiography is widely used in dental practice. One of the most common types is Photo Stimulated Phosphor Plate (PSP).Objective:The aims of this experimental study were to evaluate the impacts of different combinations of storage conditions and varying delays in reading of digital images captured using PSPs.Methods:Standardized images of a step wedges were obtained using PSPs from the Digora digital systems. Plates were exposed and immediately scanned to produce the baseline gold standard. The plates were re-exposed and stored in four different storage conditions: white light, yellow light, natural light environment and dark room, then scanned after 10 and 30 minutes and 4 and 8 hours. Objective analysis was conducted by density measurements and the data were analyzed statistically using GEE test. Subjective analysis was performed by two oral and maxillofacial radiologists and the results were analyzed using McNemar’s test.Results:The results from GEE analysis show that in the natural light environment, the densities in 10 minutes did not differ from the baseline. The mean densities decreased significantly during the time in all environments. The mean densities in step 2 for the dark room environment decreased with a slighter slope in comparison to yellow environment significantly.Conclusion:PSP images showed significant decrease in the density in plates scanned for 10 minutes or longer after exposure which may not be detected clinically. The yellow light environment had a different impact on the quality of PSP images. The spatial resolution did not change significantly with time.
机译:背景:如今,数字放射成像技术已广泛应用于牙科实践中。最常见的一种类型是光刺激荧光板(PSP)。目的:本实验研究的目的是评估存储条件的不同组合以及使用PSP捕获的数字图像读取时延变化带来的影响。使用Digora数字系统的PSP获得了一个台阶楔。曝光板并立即扫描以产生基线金标准。将板再次曝光并在四种不同的存储条件下存储:白光,黄光,自然光环境和暗室,然后在10和30分钟以及4和8小时后扫描。通过密度测量进行客观分析,并使用GEE检验对数据进行统计分析。由两名口腔颌面放射科医生进行主观分析,并使用McNemar检验对结果进行分析。结果:GEE分析的结果表明,在自然光环境下,10分钟内的密度与基线无差异。在所有环境中,平均密度在这段时间内显着下降。与黄色环境相比,暗室环境中步骤2的平均密度显着降低。结论:PSP图像显示曝光后扫描10分钟或更长时间的平板密度显着下降,这在临床上可能无法检测到。黄光环境对PSP图像的质量有不同的影响。空间分辨率没有随时间显着变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号