...
首页> 外文期刊>The Journal of Veterinary Medical Science >Quantitative Evaluation of Contrast Enhanced Transcranial Doppler Signal using Galactose Based Echo-Contrast Agent in Dogs
【24h】

Quantitative Evaluation of Contrast Enhanced Transcranial Doppler Signal using Galactose Based Echo-Contrast Agent in Dogs

机译:基于半乳糖的回声造影剂在犬中对比增强的经颅多普勒信号的定量评估

获取原文

摘要

References(32) Transcranial Doppler ultrasonography (TCD) is hindered by insufficient ultrasound penetration through the temporal bone. The use of echo-contrast agents to enhance the Doppler signal is an important step toward the solution of this problem. The aim of the present study was to investigate the tolerability and diagnostic value of the intravenous echo-contrast agent, Levovist®. Levovist® was administered intravenously in 8 dogs with two doses (0.2 and 0.3 ml/kg) at different concentrations (300 and 400 mg/ml). In right middle cerebral artery (RMCA), the duration and degree of the signal enhancement were measured by TCD. All 32 administrations of Levovist® produced an increase in TCD signal of the RMCA without complications. The first assessable pulse curve could be seen on the screen after 4 to 7 seconds after injection. There was no significant difference of latency period between different concentration and dosage. The signal amplitude was increased homogeneously by more than 30 dB when 0.3 ml/kg with 300 mg/ml concentration of Levovist® and 0.2 and 0.3 ml/kg with 400 mg/ml concentration were administered. There was no significant difference in the duration of optimal contrasting between 0.3 ml/kg with 300 mg/ml concentration of Levovist® and 0.2 and 0.3 ml/kg with 400 mg/ml concentration. The duration of the signal enhancement was 144 to 422 seconds, depending on the degree of concentration and dose of administration. Optimal TCD signal enhancement of RMCA was obtained using 0.3 ml/kg with 300 mg/ml concentration of Levovist® in dogs, which is considered to provide quality visualization.
机译:参考文献(32)经颅多普勒超声检查(TCD)受超声不足以穿透颞骨的影响。使用回声对比剂来增强多普勒信号是解决该问题的重要一步。本研究的目的是研究静脉回声造影剂Levovist®的耐受性和诊断价值。 Levovist®以不同的浓度(300和400 mg / ml)以两种剂量(0.2和0.3 ml / kg)静脉注射给8只狗。在右脑中动脉(RMCA)中,通过TCD测量信号增强的持续时间和程度。 Levovist®的所有32次给药均使RMCA的TCD信号增加,而无并发症。注射后4至7秒后,可以在屏幕上看到第一条可评估的脉冲曲线。不同浓度和剂量的潜伏期无明显差异。当使用浓度为300 mg / ml的0.3 ml / kg和浓度为400 mg / ml的0.2和0.3 ml / kg给药时,信号幅度均匀增加30 dB以上。最佳对比的持续时间在浓度为300 mg / ml的0.3 ml / kg与浓度为400 mg / ml的0.2和0.3 ml / kg之间没有显着差异。信号增强的持续时间为144至422秒,具体取决于浓度和给药剂量。使用0.3 ml / kg浓度为300 mg / ml的Levovist®犬,可以获得RMCA的最佳TCD信号增强效果,这被认为可以提供高质量的可视化效果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号