The recently introduced first integrated whole-body PET/MR scanner allows simultaneous acquisition of PET and MRI data in humans and, thus, may offer new opportunities, particularly regardin'/> First Clinical Experience with Integrated Whole-Body PET/MR: Comparison to PET/CT in Patients with Oncologic Diagnoses
首页> 外文期刊>The Journal of Nuclear Medicine >First Clinical Experience with Integrated Whole-Body PET/MR: Comparison to PET/CT in Patients with Oncologic Diagnoses
【24h】

First Clinical Experience with Integrated Whole-Body PET/MR: Comparison to PET/CT in Patients with Oncologic Diagnoses

机译:整合式全身PET / MR的首次临床经验:在肿瘤诊断中与PET / CT的比较

获取原文
           

摘要

id="p-3">The recently introduced first integrated whole-body PET/MR scanner allows simultaneous acquisition of PET and MRI data in humans and, thus, may offer new opportunities, particularly regarding diagnostics in oncology. This scanner features major technologic differences from conventional PET/CT devices, including the replacement of photomultipliers with avalanche photodiodes and the need for MRI-based attenuation correction. The aim of this study was to evaluate the comparability of clinical performance between conventional PET/CT and PET/MR in patients with oncologic diseases. >Methods: Thirty-two patients with different oncologic diagnoses underwent a single-injection, dual-imaging protocol consisting of a PET/CT and subsequent PET/MR scan. PET/CT scans were performed according to standard clinical protocols (86 ?± 8 min after injection of 401 ?± 42 MBq of 18F-FDG, 2 min/bed position). Subsequently (140 ?± 24 min after injection), PET/MR was performed (4 min/bed position). PET images of both modalities were reconstructed iteratively. Attenuation and scatter correction as well as regional allocation of PET findings were performed using low-dose CT data for PET/CT and Dixon MRI sequences for PET/MR. PET/MR and PET/CT were compared visually by 2 teams of observers by rating the number and location of lesions suspicious for malignancy, as well as image quality and alignment. For quantitative comparison, standardized uptake values (SUVs) of the detected lesions and of different tissue types were assessed. >Results: Simultaneous PET/MR acquisition was feasible with high quality in short acquisition time (a‰¤20 min). No significant difference was found between the numbers of suspicious lesions (n = 80) or lesion-positive patients (n = 20) detected with PET/MR or PET/CT. Anatomic allocation of PET/MR findings by means of the Dixon MRI sequence was comparable to allocation of PET/CT findings by means of low-dose CT. Quantitative evaluation revealed a high correlation between mean SUVs measured with PET/MR and PET/CT in lesions (?? = 0.93) and background tissue (?? = 0.92). >Conclusion: This study demonstrates, for what is to our knowledge the first time, that integrated whole-body PET/MR is feasible in a clinical setting with high quality and in a short examination time. The reliability of PET/MR was comparable to that of PET/CT in allowing the detection of hypermetabolic lesions suspicious for malignancy in patients with oncologic diagnoses. Despite different attenuation correction approaches, tracer uptake in lesions and background correlated well between PET/MR and PET/CT. The Dixon MRI sequences acquired for attenuation correction were found useful for anatomic allocation of PET findings obtained by PET/MR in the entire body. These encouraging results may form the foundation for future studies aiming to define the added value of PET/MR over PET/CT.
机译:id =“ p-3”>最近推出的第一台集成式全身PET / MR扫描仪允许同时采集人的PET和MRI数据,因此可能提供新的机会,尤其是在肿瘤诊断方面。该扫描仪的特点是与常规PET / CT设备的主要技术差异,包括用雪崩光电二极管替换光电倍增管以及需要基于MRI的衰减校正。这项研究的目的是评估传统PET / CT和PET / MR在肿瘤疾病患者中的临床表现可比性。 >方法:对32例具有不同肿瘤学诊断的患者进行了一次单次注射,两次成像检查,包括PET / CT和随后的PET / MR扫描。根据标准临床方案进行PET / CT扫描(注射 18 F-FDG 401±±42 MBq后86±±8 min,每床位2 min)。随后(注射后140±24分钟),进行PET / MR(4分钟/床位)。两种方式的PET图像都经过迭代重建。使用PET / CT的低剂量CT数据和PET / MR的Dixon MRI序列进行衰减和散射校正以及PET发现的区域分配。 2组观察员通过视觉比较PET / MR和PET / CT,对可疑恶性病变的数量和位置以及图像质量和对齐方式进行了评级。为了进行定量比较,评估了检测到的病变和不同组织类型的标准化摄取值(SUVs)。 >结果:在短时间内(≥20分钟)可以同时进行高质量的PET / MR采集。用PET / MR或PET / CT检测到的可疑病变( n = 80)或病变阳性患者( n = 20)的数量无显着差异。通过Dixon MRI序列在解剖学上分配PET / MR表现与通过低剂量CT进行PET / CT表现的分配具有可比性。定量评估显示,用PET / MR和PET / CT测量的平均SUV在病变(Δε= 0.93)和背景组织(Δε= 0.92)之间具有高度相关性。 >结论:这项研究表明,就我们所知,这是首次在临床环境中以高质量和较短的检查时间整合全身PET / MR是可行的。 PET / MR的可靠性与PET / CT的可靠性相当,可以检测出可疑肿瘤患者的高代谢性病变。尽管采用了不同的衰减校正方法,但在PET / MR和PET / CT之间,示踪剂在皮损和背景中的摄取仍具有很好的相关性。发现通过衰减校正获得的Dixon MRI序列可用于将PET / MR获得的PET结果在解剖学上分配给整个人体。这些令人鼓舞的结果可能为将来的研究奠定基础,这些研究旨在确定PET / MR相对于PET / CT的附加值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号