首页> 外文期刊>The Journal of Nuclear Medicine >Diagnostic Reference Levels of CT Radiation Dose in Whole-Body PET/CT
【24h】

Diagnostic Reference Levels of CT Radiation Dose in Whole-Body PET/CT

机译:全身PET / CT中CT辐射剂量的诊断参考水平

获取原文
   

获取外文期刊封面封底 >>

       

摘要

id="p-2">The role of CT in PET/CT imaging includes acquisition techniques for diagnostic, anatomic localization, and attenuation correction purposes. Diagnostic reference levels of the volumetric CT dose index (CTDIvol) are available for dedicated CT procedures on selected body regions, but similar reference levels for whole-body CT used in PET/CT examinations are limited. This work reports CTDIvol values from sites that conduct whole-body oncologic PET/CT examinations and participated in the scanner validation program of the Society of Nuclear Medicine and Molecular Imaging Clinical Trials Network. >Methods: From 2010 to 2014, a total of 154 sites submitted CT acquisition parameters used in their clinical 18F-FDG PET/CT oncology protocols. From these parameters, the CTDIvol was estimated using the ImPACT CTDI dosimetry tables. Histograms of CTDIvol values were created for each year, and descriptive statistics, including mean, median, and 75th percentile, were reported. Repeated-measures ANOVA was performed to determine whether significant differences occurred between reporting years. >Results: A wide range of technical parameters was reported, most notably in tube current. Between 2010 and 2014, the median CTDIvol ranged from 4.9 to 6.2 mGy and the 75th percentile from 9.7 to 10.2 mGy. There was no significant change in CTDIvol between reporting years (repeated-measures ANOVA, P = 0.985). >Conclusion: The 75th percentile CTDIvol reported in this work was 9.8 mGy averaged over all reporting years. These data provide a resource for establishing CTDIvol reference values specific to performing CT in PET/CT whole-body examinations. The wide ranges of CT acquisition parameters reported by sites suggest that CTDIvol reference levels may be beneficial for optimization of CT protocols.
机译:id =“ p-2”> CT在PET / CT成像中的作用包括用于诊断,解剖定位和衰减校正目的的采集技术。体积CT剂量指数的诊断参考水平(CTDI vol )可用于特定身体部位的专用CT程序,但是在PET / CT检查中使用的全身CT的相似参考水平有限。这项工作报告了进行全身肿瘤PET / CT检查并参加了核医学和分子影像临床试验网络协会的扫描仪验证程序的站点的CTDI vol 值。 >方法:从2010年到2014年,共有154个站点提交了其临床 18 F-FDG PET / CT肿瘤学方案中使用的CT采集参数。根据这些参数,使用ImPACT CTDI剂量测定表估算CTDI vol 。每年创建CTDI vol 值的直方图,并报告描述性统计数据,包括平均值,中位数和第75个百分位数。重复测量方差分析用于确定报告年度之间是否发生了显着差异。 >结果:报告了各种各样的技术参数,最显着的是电子管电流。在2010年至2014年之间,CTDI vol 中位数介于4.9至6.2 mGy之间,第75个百分位数介于9.7至10.2 mGy之间。在报告年度之间,CTDI vol 没有显着变化(重复测量ANOVA, P = 0.985)。 >结论:这项工作中报告的第75个百分位数CTDI vol 在所有报告年中平均为9.8 mGy。这些数据为建立专门在PET / CT全身检查中执行CT的CTDI vol 参考值提供了资源。网站报道的大量CT采集参数表明CTDI vol 参考水平可能对优化CT方案有益。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号