...
首页> 外文期刊>The Journal of Advanced Prosthodontics >Comparison of removal torques of SLActive? implant and blasted, laser-treated titanium implant in rabbit tibia bone healed with concentrated growth factor application
【24h】

Comparison of removal torques of SLActive? implant and blasted, laser-treated titanium implant in rabbit tibia bone healed with concentrated growth factor application

机译:比较SLActive的去除扭矩?集中生长因子治疗的兔胫骨中植入和经喷砂,激光处理的钛合金植入物愈合

获取原文

摘要

PURPOSE The purpose of this study was to compare the removal torques of a chemically modified SLActive implant and a blasted, laser-treated (BLT) implant, which were soaked in saline for 2 weeks after their surface modifications. The removal torques of the two implants were measured 4 weeks after their implantation into the bone defect area in rabbit tibias with concentrated growth factor (CGF) application. MATERIALS AND METHODS To make artificial bone defects in the cortical layers of both tibias, an 8-mm diameter trephine bur was used. Then, prepared CGF was applied to the bony defect of the left tibia, and the bony defect of the right tibia was left unfilled. Four weeks later, the surgical sites of 16 rabbits were re-exposed. For 8 rabbits, the SLActive implants (Straumann, Switzerland) were inserted in the left tibia, and the BLT implants (CSM implant, Daegu, Korea) were inserted in the right tibia. For other rabbits, the BLT implants were inserted in the left tibia, and the SLActive implants were inserted in the right. Four weeks afger the insertion, torque removal was measured from 4 rabbits exterminated via CO2 inhalation. RESULTS No significant difference was observed between removal torques of the BLT implant and the SLActive implant ( P >.05). CONCLUSION It was found that BLT surface modification exhibited excellent osseointegration. In addition, CGF application did not affect the insertion and removal torque of the implants.
机译:目的本研究的目的是比较化学改性的SLActive植入物和喷砂的激光处理(BLT)植入物的去除扭矩,将它们在表面改性后浸泡在盐水中2周。在使用集中生长因子(CGF)施用兔胫骨的骨缺损区域植入4周后,测量了这两种植入物的去除扭矩。材料和方法为了在两个胫骨的皮质层中制造人造骨缺损,使用了直径为8毫米的硬脑膜钻。然后,将制备的CGF施用于左胫骨的骨缺损,并保持右胫骨的骨缺损。四周后,重新暴露了16只兔子的手术部位。对于8只兔子,将SLActive植入物(瑞士的Straumann)插入左胫骨,将BLT植入物(CSM的植入物,韩国大邱)插入右胫骨。对于其他兔子,将BLT植入物插入左侧胫骨,将SLActive植入物插入右侧。插入后4周,测量了通过吸入CO 2 灭绝的4只兔子的扭矩去除。结果BLT植入物和SLActive植入物的去除扭矩之间没有观察到显着差异(P> .05)。结论发现BLT表面改性表现出优异的骨整合。此外,CGF的使用不会影响植入物的插入和移除扭矩。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号