【24h】

The use of infrared thermometry for the detection of fever

机译:使用红外测温仪检测发烧

获取原文
           

摘要

The use of tympanic thermometry is attractive in primary care, but a recent systematic review highlighted the paucity of data comparing tympanic thermometry with conventional methods. We report a study of 94 preschool children presenting to primary care in the United Kingdom (UK) with acute cough in whom tympanic infrared and axillary mercury thermometry are compared. Infrared thermometry showed poor agreement, poor sensitivity and high specificity. Infrared thermometry is too insensitive to be used as a screening test for fever, but when fever is already suspected, for example by touch, it may be useful as a ‘rule in’ test.
机译:鼓膜测温法在初级保健中很有吸引力,但是最近的系统综述强调了很少有数据比较鼓膜测温法和传统方法。我们报告了一项针对94名学龄前儿童的研究,这些学龄儿童在英国(UK)接受了急性咳嗽的急性咳嗽治疗,并比较了鼓膜红外和腋窝汞测温法。红外测温仪显示一致性差,灵敏度差和特异性高。红外测温仪太不灵敏,无法用作发烧的筛查测试,但如果已经怀疑发烧(例如通过触摸),则可以将其用作“入规”测试。