首页> 外文期刊>Quantitative Imaging in Medicine and Surgery >Pulsatile motion of trabecular meshwork in a patient with iris cyst by phase-sensitive optical coherence tomography: a case report
【24h】

Pulsatile motion of trabecular meshwork in a patient with iris cyst by phase-sensitive optical coherence tomography: a case report

机译:相敏光学相干断层扫描在虹膜囊肿患者小梁网脉动中的一例

获取原文
           

摘要

A 45-year-old man was diagnosed with a 3 mm × 3 mm iris cyst located at 9 o’clock behind iris and protruding into temporal angle by slit lamp examination, gonioscopy, and ultrasound biomicroscopy (UBM). Phase-sensitive optical coherence tomography (PhS-OCT) was applied on this case for the quantitative measurements of trabecular meshwork (TM) motion. The frequency of TM motion was with the same rhythm of the patient’s peripheral pulse. Its amplitude on the closed angle region showed significant smaller than the open angle region. PhS-OCT can be a useful tool for the diagnosis and follow-up in ocular diseases surrounding iridocorneal angle.
机译:一名45岁的男子被诊断出3毫米×3毫米虹膜囊肿,位于虹膜后9点,并通过裂隙灯检查,角膜镜检查和超声生物显微镜(UBM)突出到颞角。在这种情况下,将相敏光学相干断层扫描(PhS-OCT)应用于小梁网(TM)运动的定量测量。 TM运动的频率与患者外周脉搏的节奏相同。其在闭合角度区域上的振幅显示出明显小于打开角度区域。 PhS-OCT可以作为诊断和随访虹膜角膜角周围眼病的有用工具。