Evaluation of a new immunoassay for chromogranin A measurement on the Kryptor system

机译:评估system系统中嗜铬粒蛋白A的新免疫测定

获取原文
       

摘要

Background Chromogranin A (CgA) is a biomarker for neuroendocrine tumors (NETs). The aims of this study were to evaluate differences in measurement between the ThermoFisher Brahms CgA Kryptor assay and the CisBio assay and to investigate the influence of patient covariates. Temperature stability of CgA using both assays was determined. Design and Methods 406 patients were analyzed for serum CgA using both assays. We performed a comparison study to determine whether several patient covariates (gender, use of protein pump inhibitors, impaired kidney function, referral department and tumor location) influenced the results. For the stability study, pooled serum samples were aliquoted and stored at different storage temperatures (room temperature, 4°C and ?20°C) until assayed. In addition, 15 individual samples were evaluated after storage at 4°C using the Kryptor assay. Results Differences in measured concentrations between the assays were statistically significant. Passing & Bablok fit showed ln Y (Kryptor)=1.05ln X (CisBio) – 0.20 with a bias of 1.0% after logarithmic transformation. Patient covariates were not associated. Patients? sera showed variable stability for CgA in the Kryptor assay at room temperature and 4°C, whereas the recovery in the CisBio assay was stable at both temperatures. Conclusion Differences in measured CgA concentration between the assays could not be explained by the investigated patient covariates. Serum should be stored at –20°C prior to determination using the Kryptor assay. Highlights ? A Kryptor assay measured significant higher levels of CgA compared with CisBio. ? Difference between Kryptor and CisBio not explained by patient covariates in this study. ? Storage at room temperature and 4 °C should be avoided when using the Kryptor assay.
机译:背景嗜铬粒蛋白A(CgA)是神经内分泌肿瘤(NETs)的生物标记。这项研究的目的是评估ThermoFisher Brahms CgA rypto测定法和CisBio测定法之间的测量差异,并研究患者协变量的影响。使用两种测定法测定CgA的温度稳定性。设计与方法使用这两种方法对406例患者的血清CgA进行了分析。我们进行了一项比较研究,以确定是否有几个患者协变量(性别,使用蛋白泵抑制剂,肾功能受损,转诊科和肿瘤位置)是否影响结果。为了进行稳定性研究,将合并的血清样品等分,并在不同的存储温度(室温,4°C和?20°C)下存储,直至进行分析。另外,在4℃下储存后,使用Kryptor测定法评估了15个单独的样品。结果测定之间的浓度差异具有统计学意义。 Passing和Bablok拟合显示对数转换后ln Y(K)= 1.05ln X(CisBio)– 0.20,偏差为1.0%。患者协变量不相关。耐心?血清在室温和4°C下的K分析中显示出对CgA可变的稳定性,而CisBio分析中的回收率在两个温度下均稳定。结论所研究的患者协变量无法解释这些测定之间CgA浓度的差异。使用the测定法测定之前,应将血清保存在–20°C。强调 ?与CisBio相比,Kryptor分析测得的CgA水平明显更高。 ?在这项研究中,患者协变量并未解释K与CisBio之间的差异。 ?使用the分析时,应避免在室温和4°C下保存。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号