首页> 外文期刊>Polish Journal of Radiology >Evaluation of usefulness of scintigraphic imaging in diagnosis of intrathecal drug delivery system malfunction – a preliminary report
【24h】

Evaluation of usefulness of scintigraphic imaging in diagnosis of intrathecal drug delivery system malfunction – a preliminary report

机译:闪烁成像在鞘内给药系统故障诊断中的实用性评估–初步报告

获取原文
           

摘要

Background Implantable intrathecal drug delivery systems (IDDS) are basic tool enabling chronic intrathecal pharmacotherapy. Lack of expected clinical results of IDDS therapy necessitates search for the cause with the help of diagnostic imaging methods among other things. Beside radiological techniques, it is also possible to visually assess IDDS systems by nuclear medicine methods. In this study we assess utility of radioisotopic methods in differential diagnosis of failure of therapy with IDDS systems. Material and Methods Scintigraphic studies were performed in selected patients with neurological diseases associated with spasticity, who had IDDS system implanted and were unable to maintain satisfying clinical effect of inrathecally infused baclofen. After emptying the IDDS system of the drug, radiotracer (99mTc-DTPA) solution was injected into the pump reservoir. Subsequently, a series of scintigraphic images was registered, demonstrating passage and distribution of the infused radiotracer. Results In all investigated cases, scintigraphic study resulted in acquiring relevant additional diagnostic information. Normal or disrupted distribution of radiotracer in spinal canal allowed for a diagnosis drug resistance or demonstrated presence of arachnoid adhesions respectively. Early appearance of radiotracer in blood was considered a proof of leak. Our examinations had decisive influence on further patient treatment, allowing for diagnosis of drug resistance in one patient or complication related to IDDS system in three other cases including breakage of a catheter, pump malfunction and arachnoid adhesions. Conclusions Scintigraphic methods carry significant amount of information facilitating final diagnosis of the cause of IDDS therapy failure. They should become an important element complementing the diagnostic strategy in patients with suspected failure of intrathecal drug administration systems. Interpretation of radioisotopic studies, since they are purely functional, must be performed in strict relation to clinical data and radiological examinations as they carry indispensable, basic information regarding morphology.
机译:背景技术植入式鞘内给药系统(IDDS)是实现慢性鞘内药物治疗的基本工具。 IDDS治疗的预期临床结果缺乏,因此必须借助诊断成像方法寻找原因。除了放射技术,还可以通过核医学方法目视评估IDDS系统。在这项研究中,我们评估了放射性同位素方法在IDDS系统治疗失败的鉴别诊断中的效用。材料与方法对某些患有痉挛性神经系统疾病的患者进行了闪烁扫描研究,这些患者植入了IDDS系统并且不能维持令人满意的经静脉输注巴氯芬的临床效果。排空药物的IDDS系统后,将放射性示踪剂(99mTc-DTPA)溶液注入泵储液器中。随后,记录了一系列闪烁显像图像,表明了所注入的放射性示踪剂的通过和分布。结果在所有调查的病例中,闪烁显像研究均获得了相关的附加诊断信息。放射性示踪剂在椎管内的正常或破坏分布可分别诊断为耐药性或证实存在蛛网膜粘连。血液中放射性示踪剂的早期出现被认为是泄漏的证据。我们的检查对进一步的患者治疗具有决定性的影响,可以帮助诊断一名患者的耐药性,或在其他三种情况下诊断与IDDS系统相关的并发症,包括导管破裂,泵故障和蛛网膜粘连。结论闪烁扫描法可携带大量信息,有助于最终诊断IDDS治疗失败的原因。它们应成为补充鞘内给药系统故障的患者诊断策略的重要元素。由于放射性同位素研究纯粹是功能性的,因此必须严格按照临床数据和放射学检查进行解释,因为它们具有有关形态学必不可少的基本信息。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号