Comparison of Lateral Thermal Spread Using Monopolar and Bipolar Diathermy, and the Bipolar Vessel Sealing System ThermoStapler? During Thyroidectomy

机译:使用单极和双极透热法和双极容器密封系统ThermoStapler进行横向热扩散的比较?甲状腺切除术

获取原文
           

摘要

Comparison of Lateral Thermal Spread Using Monopolar and Bipolar Diathermy, and the Bipolar Vessel Sealing System ThermoStapler? During ThyroidectomyElectric devices enabling the maintenance of haemostasis during surgery have found application in modern thyroidectomy procedures. The haemostatic effect is associated with generation of heat, which apart from the intended result may bring about thermal tissue injury.The aim of the study was to determine the thermal spread around the active tip of electric devices in the operating field during total thyroidectomy, and the safe temperature range during the operation of studied devices.Materials and methods. Over 14 months from December 2009 until January 2011, 76 total thyroidectomy procedures were analysed. The surgeries employed mono- and bipolar diathermy as well as the ThermoStapler? bipolar vessel sealing system. During the procedures, the thermal spread around the active tips of used electric devices was recorded with the use of high-definition camera. Comparable 5-second periods of electric device use at two power ranges (30 W and 50 W) were selected from the recorded material. The highest temperature of the active tip of electric devices was determined, and the 42°C isotherm was found with the use of computer image analysis, thus determining the safe distance of important anatomic structures from the active tip of the electric device.Results. The temperature spread around the active tips of electric devices was recorded and the 42°C isotherm was determined. The diameter of this isotherm at the end of operation differed statistically significantly depending on the type of electric devices and power settings. The highest temperature, at both power ranges, was recorded for the bipolar vessel sealing system, while the lowest - for bipolar diathermy; at the same time a significantly lower 42°C isotherm diameter was found for ThermoStapler? as compared with other devices. In all studied cases, the largest heat spread was found for monopolar diathermy.Conclusions. The mean safe distance of the active tip of an electric device from important anatomic structures is 5 mm and depends on the device type and its power settings. Monopolar diathermy causes the strongest heating of surrounding tissues, and the ThermoStapler? bipolar vessel sealing system, despite producing the highest temperature during operation, causes relatively small thermal injury to the surrounding tissues.
机译:使用单极和双极透热法和双极容器密封系统ThermoStapler进行横向热扩散的比较?甲状腺切除术期间在现代甲状腺切除术过程中发现了能够在手术过程中维持止血的电动设备。止血作用与热量的产生有关,除了预期的结果以外,还可能导致组织热损伤。研究的目的是确定在甲状腺全切除术中,手术区域中电子设备活动尖端周围的热扩散,以及被研究设备运行期间的安全温度范围。材料和方法。从2009年12月到2011年1月的14个月中,共分析了76例甲状腺切除术。手术采用了单极和双极透热疗法以及ThermoStapler?双极血管密封系统。在检查过程中,使用高清摄像头记录了使用过的电子设备的活动尖端周围的热量分布。从记录的材料中选择了在两个功率范围(30 W和50 W)下可比较的5秒钟电气设备使用时间。确定了电子设备活动尖端的最高温度,并通过计算机图像分析发现了42°C等温线,从而确定了重要解剖结构与电子设备活动尖端的安全距离。记录电子设备活动尖端周围的温度分布,并确定42°C等温线。操作结束时,该等温线的直径在统计上显着不同,具体取决于电气设备的类型和功率设置。双极血管密封系统在两个功率范围内记录的最高温度,而双极透热则最低。同时发现ThermoStapler?的等温线直径明显降低了42°C?与其他设备相比。在所有研究的案例中,单极透热疗法的热扩散最大。电气设备的活动尖端与重要的解剖结构的平均安全距离为5 mm,并取决于设备类型及其功率设置。单极透热疗法会引起周围组织的最强热量,而ThermoStapler?尽管双极血管密封系统在操作过程中会产生最高温度,但对周围组织的热损伤相对较小。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号