...
首页> 外文期刊>Pesquisa Veterinária Brasileira >Sensibilidade e especificidade do 'California Mastitis Test' como recurso diagnóstico da mastite subclínica em rela??o à contagem de células somáticas
【24h】

Sensibilidade e especificidade do 'California Mastitis Test' como recurso diagnóstico da mastite subclínica em rela??o à contagem de células somáticas

机译:“ California Mastitis Test”作为亚临床性乳腺炎与体细胞计数相关的诊断资源的敏感性和特异性

获取原文
           

摘要

The California Mastitis Test (CMT) is a simple and widely used diagnostic tool for subclinical mastitis. It is used even in areas where laboratory facilities are available for diagnosis and monitoring program purposes. CMT usually score 1-5, where 1 indicates a completely negative reaction and 2-5 increasing degrees of inflammatory reaction of the udder. The reactions 2-5, 3-5 or 4-5 may be considered as indicative of subclinical mastitis, bever, may produce either false-positive or false-negative results. The aim of this study waecause they are related to an increase of the somatic cell count (SCC) in the milk. This variation, hows to assess the sensitivity and specificity of the CMT in comparison with SCC. A total of 3,012 quarter milk samples from 760 lactating cows were examined. CMT was evaluated at the moment of sampling at cow side and SCC in the laboratory, with a fluoro-opto-electronic method (Fossomatic 90). The average CCS (x 1,000 cells/ml) for CMT scores were: 1 (79.9), 2 (333.5), 3 (670.3), 4 (1,354.0) and 5 (4,455.6). Three options for CMT interpretation were evaluated in relation to a range of CCS, starting from 100,000 cells/ml: (a) 1 versus 2, 3, 4, and 5; (b) 1 and 2 versus 3, 4 and 5; and (c) 1, 2 and 3 versus 4 and 5. The sensitivities of CMT scoring to detect quarters with SCC 200,000/ml were 79%, 61% e 34% for options a, b and c, respectively. The sensitivities of CMT scores for SCC 500,000/ml for options a, b and c, were, respectively, 93%, 82% e 54%. The sensitivity of CMT scores to identify subclinical mastitis was satisfactory (above 80%) when options b and c were used. The interpretation of CMT score 3 as negative for subclinical mastitis was considered as adequate (sensitivity around 80%) only when CCS ranged between 1,200,000 and 1,400,000 cells/ml. The specificities of CMT scoring for CCS of 200,000 and 500,000 were, respectively, 90% and 80% (option a), 97% and 90% (option b) and 99% and 97% (option c).
机译:加州乳腺炎测试(CMT)是一种用于亚临床乳腺炎的简单且广泛使用的诊断工具。即使在实验室设备可用于诊断和监视程序目的的区域中,也可以使用它。 CMT通常评分为1-5,其中1表示完全阴性反应,2-5表示乳腺炎性反应程度增加。反应2-5、3-5或4-5可被认为是亚临床乳腺炎的指示,bever可能会产生假阳性或假阴性结果。这项研究的目的是因为它们与牛奶中体细胞计数(SCC)的增加有关。与SCC相比,这种变化如何评估CMT的敏感性和特异性。共检查了来自760头泌乳牛的3,012个季度牛奶样品。在实验室进行牛侧采样和SCC采样时,采用氟光电方法(Fossomatic 90)对CMT进行了评估。 CMT评分的平均CCS(x 1,000细胞/ ml)为:1(79.9),2(333.5),3(670.3),4(1,354.0)和5(4,455.6)。相对于CCS范围,评估了三种解释CMT的方法,从100,000个细胞/ ml开始:(a)1对2、3、4、5; (b)1和2与3、4和5; (c)1、2和3与4和5。CMT得分检测SCC> 200,000 / ml的四分之一的敏感性分别为选项a,b和c的79%,61%e 34%。对于选项a,b和c,SCC大于500,000 / ml的CMT分数的敏感性分别为93%,82%和54%。当使用选项b和c时,CMT评分识别亚临床乳腺炎的敏感性令人满意(超过80%)。仅当CCS介于1,200,000和1,400,000细胞/ ml之间时,才认为将CMT评分3解释为亚临床乳腺炎为阴性(敏感性约80%)。对于200,000和500,000的CCS,CMT得分的特异性分别为90%和80%(选项a),97%和90%(选项b)以及99%和97%(选项c)。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号