style="text-align: left;">At the Vienna airport an extension to the runway was constructed as a prestressed concrete pavement. This runway extension measured approximately 3,280 ft. by 147 ft. 6 in. A new taxiway  approximately 3,609 ft. by 73 ft. 8 in. and a parking apron for jets 1,425 ft. by 172 ft. were also constructed of prestressed concrete. The slabs for these areas were constructed in sections. The thickness of  these slabs was 6 in. and each section had a width of 24 ft. 8 in. and was from 328 ft. to 410 ft. long. (Fig. 1.) Pretensioning was applied in the longitudinal direction. In the transverse direction the slab  as posttensioned with cables consisting of 24 wires, each encased in conduit tubing. The wires have a diameter of approximately 5/32 in., a yield stress of 206,000 psi and a tensile strength of  241,500 psi. The initial prestress was 227 psi in the longitudinal direction and 142 psi in the transverse direction. Both prestressed reinforcement lies in the center of the slab (Fig. 2). In the longitudinal direction 80 wires are placed in two layers. The transverse elements are spaced app. 9 ft. apart. Per 1 sq. yd. of concrete slab approximately 6% lb. of wire was used.
机译:style =“ text-align:left;”>在维也纳机场,跑道的延伸被构造为预应力混凝土路面。跑道延伸约3,280英尺乘147英尺6英寸。一条新的滑行道约3,609英尺乘73英尺8英寸,以及用于喷气机1,425英尺乘172英尺的停车停机坪也由预应力混凝土制成。这些区域的平板是按部分构造的。这些平板的厚度为6英寸,每个部分的宽度为24英尺8英寸,长度为328英尺至410英尺。 (图1。)在纵向上施加预拉伸。在横向方向上,平板用24根电线组成的电缆进行预张紧,每根都包裹在导管中。这些线的直径约为5/32英寸,屈服应力为206,000 psi,拉伸强度为241,500 psi。初始预应力在纵向为227 psi,在横向为142 psi。两种预应力钢筋都位于板的中心(图2)。在纵向方向上,将电线分成两层放置80条。横向元素间隔开。相距9英尺每1平方码大约使用6%磅的钢丝。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号