...
首页> 外文期刊>Shiraz University of Medical Sciences >Can the Accuracy of Home Blood Glucose Monitors be affected by the Received Signal Strength of 900 MHz GSM Mobile Phones?
【24h】

Can the Accuracy of Home Blood Glucose Monitors be affected by the Received Signal Strength of 900 MHz GSM Mobile Phones?

机译:900 MHz GSM移动电话的接收信号强度会影响家用血糖监测仪的准确性吗?

获取原文
           

摘要

Background: People who use home blood glucose monitors may use their mobile phones in the close vicinity of medical devices. This study is aimed at investigating the effect of the signal strength of 900 MHz GSM mobile phones on the accuracy of home blood glucose monitors. Methods: Sixty non-diabetic volunteer individuals aged 21 - 28 years participated in this study. Blood samples were analyzed for glucose level by using a common blood glucose monitoring system. Each blood sample was analyzed twice, within ten minutes in presence and absence of electromagnetic fields generated by a common GSM mobile phone during ringing. Blood samples were divided into 3 groups of 20 samples each. Group 1: exposure to mobile phone radiation with weak signal strength. Group2: exposure to mobile phone radiation with strong signal strength. Group3: exposure to a switched–on mobile phone with no signal strength. Results: The magnitude of the changes in the first, second and third group between glucose levels of two measurements (?ΔC?) were 7.4±3.9 mg/dl, 10.2±4.5 mg/dl, 8.7±8.4 mg/dl respectively. The difference in the magnitude of the changes between the 1st and the 3rd groups was not statistically significant. Furthermore, the difference in the magnitude of the changes between the 2nd and the 3rd groups was not statistically significant.  Conclusion: Findings of this study showed that the signal strength of 900 MHz GSM mobile phones cannot play a significant role in changing the accuracy of home blood glucose monitors.
机译:背景:使用家用血糖监测仪的人可能会在医疗设备附近使用手机。这项研究旨在调查900 MHz GSM手机的信号强度对家用血糖监测仪准确性的影响。方法:60名21-28岁的非糖尿病志愿者参加了这项研究。通过使用通用血糖监测系统分析血液样本中的葡萄糖水平。在振铃过程中,在有无通用GSM移动电话产生的电磁场的情况下,在十分钟之内对每个血液样本进行两次分析。血液样本分为3组,每组20个样本。第一组:暴露于信号强度较弱的手机辐射下。第二组:暴露于具有强信号强度的手机辐射中。第3组:暴露于无信号强度的开机状态。结果:在第一,第二和第三组中,两次测量的葡萄糖水平之间的变化幅度(ΔC2)为7.4±3.9mg / dl,10.2±4.5mg / dl,8.7±8.4mg。 / dl。第一组和第三组之间变化幅度的差异无统计学意义。此外,第二组和第三组之间的变化幅度差异没有统计学意义。结论:这项研究的结果表明,900 MHz GSM手机的信号强度在改变家用血糖监测仪的准确性方面没有发挥重要作用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号