The mass attenuation coefficients for compounds of biomedically important some elements (Na, Mg, Al, Ca, and Fe) have been measured by using an extremely narrow collimated-beam transmission method in the energy 59.5 keV. Total electronic, atomic, and molecular cross sections, effective atomic numbers, and electron densities have been obtained by using these results. Gamma-rays of 241Am passed through compounds have been detected by a high-resolution Si(Li) detector and by using energy dispersive X-ray fluorescence spectrometer (EDXRF). Obtained results have been compared with theoretically calculated values of WinXCom and FFAST. The relative difference between the experimental and theoretical values are −9.4% to.
机译:对于生物医学上重要的某些元素(Na,Mg,Al,Ca和Fe)的化合物,其质量衰减系数已通过在59.5 keV的能量中使用极窄的准直光束传输方法进行了测量。通过使用这些结果,可以获得总的电子,原子和分子截面,有效原子序数和电子密度。 241Am穿过化合物的伽马射线已经通过高分辨率Si(Li)检测器和能量色散X射线荧光光谱仪(EDXRF)进行了检测。将获得的结果与WinXCom和FFAST的理论计算值进行了比较。实验值和理论值之间的相对差为-9.4%至。