The aim of the study was to examine the correlation between the chosen position of screws and the complications observed in patients who underwent locked plating of proximal humeral fractures. We evaluated radiographs of 367 patients treated by locked-plating for proximal humeral fractures. Radiographs were taken at one day, 6 weeks, 3 months and 6 months after surgery, and were analyzed for secondary fracture displacement, loss of fixation, cutting out of screws and necrosis of the humeral head. Secondary loss of fixation occurred in 58 cases (15.8%) and among those cutting out of screws was observed in 25 cases (6.8%). In cases of secondary loss of fixation a mean of 6.7 screws were used to fix the fracture (vs 6.6, P=0.425). There was neither significant correlation between position of screws and the occurrence of postoperative loss of fixation in Spearman correlation nor relationship from backward logistic regression analysis. Loss of fixation following locked plating of proximal humeral fractures does not relate to the number of screws and their positions in the humeral head. In consequence, anatomic fracture reduction and restoration of the humeral head-shaft angle are still important factors and should not be disregarded.Key words: proximal humeral fracture, angular stable plating, screw cutout, secondary fracture displacement, loss of fixation
机译:这项研究的目的是检查选择的螺钉位置与在肱骨近端骨折锁定钢板中观察到的并发症之间的相关性。我们评估了367例经锁定钢板治疗的肱骨近端骨折患者的X光片。术后1天,6周,3个月和6个月拍摄X射线照片,并分析其继发性骨折移位,固定丢失,螺钉切出和肱骨头坏死。继发性固定丧失58例(15.8%),其中有25例(6.8%)的螺钉切出。在继发性失去固定的情况下,平均用6.7颗螺钉固定骨折(vs 6.6,P = 0.425)。 Spearman相关性与螺钉位置与术后固定丧失的发生之间无显着相关性,也不与后向逻辑回归分析相关。肱骨近端骨折的锁定钢板固定后失去固定与螺钉的数量及其在肱骨头中的位置无关。因此,解剖性骨折的复位和肱骨头的旋转角度仍然是重要的因素,因此不容忽视。关键词:肱骨近端骨折,角稳定钢板,螺钉切开,继发性骨折移位,固定丢失

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号