首页> 外文期刊>Orbital : the Electronic Journal of Chemistry >Determination of Ethylmalonic Acid in Human Urine by Ion Chromatography with Suppressed Conductivity
【24h】

Determination of Ethylmalonic Acid in Human Urine by Ion Chromatography with Suppressed Conductivity

机译:抑制电导的离子色谱法测定人尿中的乙基丙二酸

获取原文
           

摘要

We present here a new method for the determination of EMA in urine by ion chromatography (IC) with suppressed conductivity detection. The separations on an anion exchange column have been accomplished with an optimized multi-step gradient eluent program (5 mM for 0-7 min, 5-50 mM from 7 to 30 min, 50 mM for 30-40 min, 50-5 mM from 40 to 45 min, 5mM for 45-50 min at flow-rate 0.2 mL/min) using NaOH as the eluent. The temperatures of both the column and suppressed conductivity detector were 40 °C. The suppressor current was 25 mA. The injection loop volume was 100 μL. Prior to injection, a clean-up procedure has been applied to urine samples for sulfate removal using BaCl2 precipitation followed by elimination of cationic and some organic compounds using strongly acid cation-exchange resin and C18 solid phase extraction cartridge, respectively. Concentration range of EMA for linear external calibration curve was between 0.202 -30.278 μmol/L (r2=0.999). The limit of detection and the limit of quantitation were 61 nmol/L and 202 nmol/L based on the signal-to-noise ratio equal to 3 and 10, respectively. The average recoveries of EMA for normal urine samples were between 98.2-99.3 % with less than 1.1 % relative standard deviation (RSD), and for pathological sample were between 97.2-107.8% with less than 1.9% RSD in both intra-day and inter-day assays. The average concentrations of EMA normalized against creatinine for healthy human urine samples and a pathological sample were 1.14 (0.88-1.50) and 128.95 (128.04-129.33) μmol mmol-1 creatinine, respectively.?DOI: http://dx.doi.org/10.17807/orbital.v7i2.574
机译:我们在这里介绍了一种通过抑制电导率检测的离子色谱法(IC)测定尿液中EMA的新方法。阴离子交换柱上的分离已通过优化的多步梯度洗脱液程序完成(0-7分钟为5 mM,7-30分钟为5-50 mM,30-40分钟为50 mM,50-5 mM 40分钟至45分钟,使用NaOH作为洗脱液,以5mM的流速进行45-50分钟(流速为0.2 mL / min)。色谱柱和抑制电导检测器的温度均为40°C。抑制器电流为25 mA。进样环体积为100μL。注射之前,已对尿液样品进行了清洁程序,以使用BaCl2沉淀去除硫酸盐,然后分别使用强酸阳离子交换树脂和C18固相萃取柱消除阳离子和某些有机化合物。线性外部校准曲线的EMA浓度范围为0.202 -30.278μmol/ L(r2 = 0.999)。基于信噪比分别等于3和10的检测极限和定量极限分别为61 nmol / L和202 nmol / L。正常尿液样品的平均回收率在日间和日间均在98.2-99.3%之间,相对标准偏差(RSD)小于1.1%,病理样品在97.2-107.8%之间,RSD小于1.9%天检测。健康人尿液样本和病理样本中针对肌酐标准化的EMA平均浓度分别为1.14(0.88-1.50)和128.95(128.04-129.33)μmolmmol-1肌酐。DOI:http://dx.doi。 org / 10.17807 / orbital.v7i2.574

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号