A simple, rapid, precise and eco-friendly ion chromatography (IC) method for the determination of hippuric acid (HA) in human urine was proposed in this paper. The separation was carried out an anion exchange column with 2.0mmolL~(-1) Na_2CO_3+2.0mmolL~(-1) NaHCO_3 as mobile phase at the flow-rate 0.7mLmin~(-1). A suppressed conductivity detector was used and the detection limit was 1.0μgL~(-1)(S/N=3) for hippuric acid. The analysis time for one run was 30min under the optimized IC condition. The recovery of hippuric acid was 93.2-98.0% while the relative standard deviation (RSD) was 1.4-2.3% by seven measurements.
机译:提出了一种简便,快速,精确,环保的离子色谱法测定人尿中的马尿酸(HA)。以2.0mmolL〜(-1)Na_2CO_3 + 2.0mmolL〜(-1)NaHCO_3作为流动相,以0.7mLmin〜(-1)的流速进行阴离子交换柱的分离。使用抑制电导检测器,对马尿酸的检出限为1.0μgL〜(-1)(S / N = 3)。在优化的IC条件下,一次运行的分析时间为30分钟。通过七次测量,马尿酸的回收率为93.2-98.0%,相对标准偏差(RSD)为1.4-2.3%。