ABSTRACT INTRODUCTION: Human metapneumovirus (hMPV) is an emergent human respiratory pathogen. This study aimed to evaluate the performance of direct immunofluorescence (DIF) to detect hMPV in a clinical laboratory setting. METHODS: Nasopharyngeal aspirate samples (448) of children and adults with respiratory illness were used to detect hMPV by using DIF and real time quantitative reverse transcription-polymerase chain reaction (qRT-PCR) assays. RESULTS: In all, 36 (8%) samples were positive by DIF and 94 (21%) were positive by qRT-PCR. Direct immunofluorescence specificity was 99% and sensitivity was 38%. CONCLUSIONS: DIF is not very sensitive under clinical laboratory settings.
机译:摘要:人类偏肺病毒(hMPV)是一种新兴的人类呼吸道病原体。这项研究旨在评估在临床实验室环境中直接免疫荧光(DIF)检测hMPV的性能。方法:采用DIF和实时定量逆转录-聚合酶链反应(qRT-PCR)方法,对儿童和成人呼吸道疾病的鼻咽抽吸物(448份)进行检测。结果:共有36(8%)个样品通过DIF呈阳性,而94个(21%)通过qRT-PCR呈阳性。直接免疫荧光特异性为99%,敏感性为38%。结论:DIF在临床实验室环境下不是很敏感。