ABSTRACT Objective: To describe and clinically and radiographically compare patients who underwent total knee arthroplasty (TKA) with all-polyethylene (ALP) and metal-backed (MTB) tibial implants. Methods: Patients who underwent TKA between January 1988 and December 2004 were grouped according to the type of implant received: all-polyethylene or metal-backed. Sixty patients came for evaluations, totaling 82 operated knees. Among these, 22 patients had undergone TKA only with ALP (12 unilateral and 10 bilateral cases), 33 patients only with MTB (26 unilateral and 7 bilateral cases) and five patients underwent TKA with ALP in one knee and MTB in the other. The knees were divided thus: group 1, 37 knees with ALP; and group 2, 45 knees with MTB. Results: There were no differences in clinical or functional evaluations between the groups. The mean radiolucency in the femur was 0.838 mm for the patients in group 1 and 0.356 mm for the patients in group 2 (p = 0.049). For the tibia, in the AP view, there was a mean value of 2.703 mm for group 1 and 0.733 mm for group 2 (p = 0.000). In the lateral view, the mean values for osteolysis was 0.405 mm for group 1 and 0.200 mm for group 2 (p = 0.074). Conclusions: There were no differences between the groups in the functional and clinical evaluations. However, greater radiolucency was observed in the arthroplasties with ALP, both in the femur in the lateral view and in the tibia in the AP view. Level of evidence IV – case series study.
机译:摘要目的:描述并在临床和影像学上比较采用全聚乙烯(ALP)和金属支持(MTB)胫骨植入物进行全膝关节置换(TKA)的患者。方法:根据植入物的类型对在1988年1月至2004年12月期间进行TKA的患者进行分组:全聚乙烯或金属支持。 60名患者接受了评估,总共进行了82例手术膝盖。其中22例仅接受过AKA的TKA(12例单侧和10例双侧病例),33例仅接受MTB的患者(26例单侧和7例双侧病例)和5例接受过TKA的ALP伴有一只膝关节和MTB。因此,将膝盖分为:第1组,使用ALP的37个膝盖;第2组,使用MTB进行45膝。结果:两组之间的临床或功能评估无差异。第一组患者的股骨平均放射线透明度为0.838毫米,第二组患者为0.356毫米(p = 0.049)。对于胫骨,在AP视野中,第1组的平均值为2.703 mm,第2组的平均值为0.733 mm(p = 0.000)。在侧视图中,第1组的溶骨平均值为0.405 mm,第2组的为0.200 mm(p = 0.074)。结论:各组在功能和临床评估上没有差异。然而,在侧视的股骨和在AP的胫骨中,在使用ALP的关节置换术中均观察到更高的射线透过性。证据级别IV –案例系列研究。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号