A method of on-line monitoring of the low-dropout voltage regulator's operation in a radiation environment is developed in this paper. The method had to enable detection of the circuit's degradation during exploitation, without terminating its operation in an ionizing radiation field. Moreover, it had to enable automatic measurement and data collection, as well as the detection of any considerable degradation, well before the monitored voltage regulator's malfunction. The principal parameters of the voltage regulator's operation that were monitored were the serial pnp transistor's base current and the forward emitter current gain. These parameters were procured indirectly, from the data on the voltage regulator's load and quiescent currents. Since the internal consumption current in moderately and heavily loaded devices was used, the quiescent current of a negligibly loaded voltage regulator of the same type served as a reference. Results acquired by on-line monitoring demonstrated marked agreement with the results acquired from examinations of the voltage regulator's maximum output current and minimum dropout voltage in a radiation environment. The results were particularly consistent in tests with heavily loaded devices. Results obtained for moderately loaded voltage regulators and the risks accompanying the application of the presented method, were also analyzed.
机译:本文提出了一种在线监测辐射环境中低压差稳压器工作的方法。该方法必须能够检测电路在开发过程中的退化,而不必在电离辐射场中终止电路的运行。而且,它必须能够在被监视的稳压器出现故障之前就进行自动测量和数据收集,以及检测任何明显的劣化。监视的稳压器操作的主要参数是串行pnp晶体管的基极电流和正向发射极电流增益。这些参数是从调压器的负载和静态电流数据中间接获得的。由于使用的是中度负载和重负载设备的内部消耗电流,因此可忽略负载的相同类型的稳压器的静态电流用作参考。通过在线监测获得的结果表明与在辐射环境中检查稳压器的最大输出电流和最小压降电压获得的结果非常一致。在使用重载设备进行的测试中,结果尤其一致。还分析了中等负载电压调节器获得的结果以及所提出方法的应用带来的风险。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号