首页> 外文期刊>Korean Circulation Journal >Measurement of the Carotid Intima, Media and Intima-Media Thickness with Ultrasound and New Software
【24h】

Measurement of the Carotid Intima, Media and Intima-Media Thickness with Ultrasound and New Software

机译:用超声波和新软件测量颈动脉内膜,中膜和内膜中膜厚度

获取原文
获取外文期刊封面目录资料

摘要

BACKGROUND AND OBJECTIVES: We performed this study to evaluate the feasibility and accuracy of the newly developed Korean software (KS) for measurement of the carotid intima-media thickness (IMT), which was compared with the commercial software. SUBJECTS AND METHODS: The study population consisted of 60 consecutive patients (mean of 59 years old, 27 males) undergoing transthoracic echocardiography. We measured the carotid IMT using both software packages, and also measured the intima thickness (IT) and media thickness (MT), separately, using the KS package. RESULTS: Measurement of the IMT was possible in all the study subjects with both software packages, but the separate measurements of the IT and MT was possible in only 24 patients using the KS package. The mean IMT using the commercial and KS packages were 0.727±0.157 and 0.733±0.156 mm, respectively, which were found to correlate (r=0.985, p=0.000). The mean IMT, IT and MT of the 24 patients were 0.841±0.138, 0.340±0.033 and 0.505±0.124 mm, respectively. The carotid IMT was correlated with the IT and MT and also with the IT/IMT, MT/IMT and IT/MT ratios (r=0.562, p=0.004; r=0.934, p=0.000; r=-0.809, p=0.000; r=0.591, p=0.002; r=-0.754, p=0.000, respectively). The IT was found not to correlate with the MT (r=0.369, p=0.076). Age was found to correlate with the IMT using both the commercial and KS packages (r=0.616, p=0.000; r=0.583, p=0.000, respectively), and with the MT and IT/IMT and IT/MT ratios (r=0.504, p=0.012; r=-0.538, p=0.007; r=-0.428, p=0.037), but not with the IT (r=0.300, p=0.154). CONCLUSION: The newly developed KS was feasible and accurate in measuring the carotid IMT, which can also be used to separately measure the IT and MT.
机译:背景与目的:我们进行了这项研究,以评估新开发的韩国软件(KS)用于测量颈动脉内膜中层厚度(IMT)的可行性和准确性,并与商用软件进行了比较。受试者和方法:研究人群包括60例连续接受胸腔超声心动图检查的患者(平均59岁,男27例)。我们使用这两个软件包测量了颈动脉IMT,还使用KS软件包分别测量了内膜厚度(IT)和中膜厚度(MT)。结果:使用两个软件包均可在所有研究对象中测量IMT,但是使用KS软件包仅可对24位患者进行IT和MT的单独测量。使用商业包装和KS包装的平均IMT分别为0.727±0.157和0.733±0.156 mm,发现具有相关性(r = 0.985,p = 0.000)。 24例患者的平均IMT,IT和MT分别为0.841±0.138、0.340±0.033和0.505±0.124mm。颈动脉IMT与IT和MT以及IT / IMT,MT / IMT和IT / MT比率相关(r = 0.562,p = 0.004; r = 0.934,p = 0.000; r = -0.809,p = 0.000; r = 0.591,p = 0.002; r = -0.754,p = 0.000)。发现IT与MT不相关(r = 0.369,p = 0.076)。使用商业软件包和KS软件包,发现年龄与IMT相关(分别为r = 0.616,p = 0.000; r = 0.583,p = 0.000),以及MT和IT / IMT和IT / MT比率(r = 0.504,p = 0.012; r = -0.538,p = 0.007; r = -0.428,p = 0.037),但对于IT则不是(r = 0.300,p = 0.154)。结论:新开发的KS在测量颈动脉IMT方面是可行和准确的,也可用于分别测量IT和MT。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号