首页> 外文期刊>Mineralogia >The Effects of Fluid Viscosity on the Orifice Rotameter
【24h】

The Effects of Fluid Viscosity on the Orifice Rotameter

机译:流体粘度对节流孔转子流量计的影响

获取原文
           

摘要

Due to the viscous shear stress, there is an obvious error between the real flow rate and the rotameter indication for measuring viscous fluid medium. At 50 cSt the maximum error of DN40 orifice rotameter is up to 35 %. The fluid viscosity effects on the orifice rotameter are investigated using experimental and theoretical models. Wall jet and concentric annulus laminar theories were adapted to study the influence of viscosity. And a new formula is obtained for calculating the flow rate of viscous fluid. The experimental data were analyzed and compared with the calculated results. At high viscosity the maximum theoretical results error is 6.3 %, indicating that the proposed measurement model has very good applicability.
机译:由于粘性剪切应力,实际流量与用于测量粘性流体介质的转子流量计指示之间存在明显的误差。在50 cSt时,DN40孔口转子流量计的最大误差高达35%。使用实验和理论模型研究了流体粘度对节流孔转子流量计的影响。壁射流和同心环流层流理论适用于研究粘度的影响。并获得了计算粘性流体流量的新公式。分析实验数据并与计算结果进行比较。在高粘度下,最大理论结果误差为6.3%,表明所提出的测量模型具有非常好的适用性。