首页> 外文期刊>Medicinski Preglad >Evaluation of effect of local administration of desoximetasone and ditranol in psoriatic lesion by applying 20MHz ultrasound
【24h】

Evaluation of effect of local administration of desoximetasone and ditranol in psoriatic lesion by applying 20MHz ultrasound

机译:应用20MHz超声评估银屑病皮损中地塞米松和二氢萘酚的局部给药效果

获取原文
获取外文期刊封面目录资料

摘要

Introduction. This prospective study was aimed at examining the modification of ultrasound characteristics of psoriatic plaques during desoximetasone and dithranol treatment. Material and Methods. The examination included 50 patients with chronic plaque-type psoriasis to whom 0.25% desoximetasone and dithranol was applied on the psoriatic lesions in the period of 21 days. The changes were measured before and every 7 days after the beginning of therapy by the combined application of Aand B-mode echosonography. Results. At the beginning of the examination, the average values of the enter echo were 0.67±0.53 mm; hypoehogen shadow 0.30±0.11 mm, and dermis thickness 3.03±1.05 mm. On the first check up, the average values of the enter echo were 0.45±0.29 mm; hypoechogen shadow 0.23±0.08 mm and dermis thickness 2.65±0.97 mm. On the second check up, the average values of the enter echo were 0.30±0.18 mm; hypoechogen shadow 0.21±0.18 mm, dermis thickness 2.18±0.82 mm. On the third check up, the average values of the enter echo were 0.24±0.17 mm; hypoechogen shadow 0.18±0.17 mm, and dermis thickness 1.8±0.69 mm. Discussion. The evaluation of the ultrasonographic characteristics revealed a significant reduction in the values in the course of the examination. Statistically significant differences were found before, during, and at the end of the examination by recording the ultrasound parameters of the epidermis and dermis and by following their modification. Conclusion. Precise determination of ultrasound parameters of epidermis and dermis and the possibility of recording their modification in a shorter or longer time interval can be used for monitoring and assessment of therapy effect of a medication.
机译:介绍。这项前瞻性研究旨在检查去氧美他松和二乙醇胺治疗期间牛皮癣斑块超声特征的改变。材料与方法。该检查包括50例慢性斑块型牛皮癣患者,在21天的时间内对银屑病皮损应用0.25%的地塞米松和二硫醇。在治疗开始之前和之后每7天通过结合使用A和B型超声检查来测量变化。结果。在检查开始时,回波的平均值为0.67±0.53 mm。次生阴影0.30±0.11 mm,真皮厚度3.03±1.05 mm。第一次检查时,回波的平均值为0.45±0.29 mm;骨质疏松症阴影0.23±0.08 mm,真皮厚度2.65±0.97 mm。在第二次检查中,回波的平均值为0.30±0.18 mm;骨质疏松症阴影0.21±0.18 mm,真皮厚度2.18±0.82 mm。在第三次检查中,回波的平均值为0.24±0.17 mm;骨质疏松症阴影0.18±0.17 mm,真皮厚度1.8±0.69 mm。讨论。超声特征的评估表明,在检查过程中其值明显降低。通过记录表皮和真皮的超声参数并遵循它们的修改,在检查之前,期间和结束时发现统计学上的显着差异。结论。精确确定表皮和真皮的超声参数以及在更短或更长的时间间隔内记录其超声变化的可能性可用于监测和评估药物的治疗效果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号