...
首页> 外文期刊>Medicine. >Infections of Cardiac Implantable Electronic Devices: A Retrospective Multicenter Observational Study
【24h】

Infections of Cardiac Implantable Electronic Devices: A Retrospective Multicenter Observational Study

机译:心脏植入式电子设备的感染:回顾性多中心观察性研究。

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Infections of cardiac implantable electronic devices (CIED) can cause significant morbidity, mortality, and financial burden. Although staphylococcal organisms account for most infections of these cardiac devices, approximately 20% of all CIED-related infections are caused by non-Staphylococcus species. Herein we describe and compare the demographics, clinical presentation, and outcomes of Staphylococcus aureus and non-staphylococcal infections of CIED. We performed a retrospective, multicenter, observational study of patients from 4 academic hospitals in Houston between 2002 and 2009. All 80 identified non-staphylococcal CIED-related infections were matched, at a 1:1 ratio, to S. aureus infections. Although the demographics and general comorbidities in the 2 study groups were relatively similar, the S. aureus group had a higher proportion of patients with coronary artery disease, diabetes mellitus, and end-stage renal disease. Additionally, 81% of S. aureus compared with only 48.5% of the non-staphylococcal CIED-related infections were health care-associated (p S. aureus group had more indwelling intravascular foreign material (p Since approximately one-fifth of all CIED-related infections are caused by non-staphylococcal organisms, and untimely antibiotic treatment can result in serious complications, it may be prudent to broaden empiric antimicrobial therapy to cover both Gram-positive and -negative bacteria, until the causative organism is identified. Abbreviations: CIED = cardiac implantable electronic devices, ESR = erythrocyte sedimentation rate, ICD = implantable cardioverter-defibrillators, MRSA = methicillin-resistant Staphylococcus aureus, MSSA = methicillin-sensitive Staphylococcus aureus, PPM = permanent pacemakers, TEE = transesophageal echocardiogram, TTE = transthoracic echocardiogram, WBC = white blood cell count.
机译:心脏植入式电子设备(CIED)的感染会导致严重的发病率,死亡率和财务负担。尽管葡萄球菌是造成这些心脏设备感染的主要原因,但所有与CIED相关的感染中约有20%是由非葡萄球菌引起的。在本文中,我们描述并比较了金黄色葡萄球菌和CIED的非葡萄球菌感染的人口统计学,临床表现和结果。我们对2002年至2009年间休斯顿的4所学术医院的患者进行了一项回顾性,多中心,观察性研究。所有80例经鉴定的非葡萄球菌CIED相关感染均与金黄色葡萄球菌感染按1:1的比例匹配。尽管两个研究组的人口统计学和一般合并症相对相似,但金黄色葡萄球菌组的冠心病,糖尿病和终末期肾病患者比例更高。此外,金黄色葡萄球菌有81%,而非金黄色葡萄球菌CIED相关感染只有48.5%,是与医疗保健相关的(p。金黄色葡萄球菌组留有更多的血管内异物(p因为约占所有CIED的五分之一,相关的感染是由非葡萄球菌引起的,不及时的抗生素治疗可能会导致严重的并发症,因此应扩大经验性的抗菌治疗,以覆盖革兰氏阳性和阴性细菌,直到确定致病菌,这才是明智的选择。 =心脏植入式电子设备,ESR =红细胞沉降率,ICD =植入式心脏除颤器,MRSA =耐甲氧西林的金黄色葡萄球菌,MSSA =耐甲氧西林的金黄色葡萄球菌,PPM =永久起搏器,TEE =经食道超声心动图,TTE =经胸WBC =白细胞计数。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号