首页> 外文期刊>Medical principles and practice: international journal of the Kuwait University, Health Science Centre >Erosive Effect of Different Soft Drinks on Enamel Surface in vitro: Application of Stylus Profilometry
【24h】

Erosive Effect of Different Soft Drinks on Enamel Surface in vitro: Application of Stylus Profilometry

机译:不同软饮料对牙釉质表面的体外腐蚀作用:测针轮廓仪的应用

获取原文
           

摘要

Objective: To assess the erosive potential of various soft drinks by measuring initial pH and titratable acidity (TA) and to evaluate enamel surface roughness using different exposure times. Materials and Methods: The initial pH of the soft drinks (group 1: Coca-Cola; group 2: orange juice; group 3: Cedevita; group 4: Guarana, and group 5: strawberry yoghurt) was measured using a pH meter, and TA was measured by titration with NaOH. Enamel samples (n = 96), cut from unerupted human third molars, were randomly assigned to 6 groups: experimental (groups 1-5) and control (filtered saliva). The samples were exposed to 50 ml of soft drinks for 15, 30 and 60 min, 3 times daily, during 10 days. Between immersions, the samples were kept in filtered saliva. Enamel surface roughness was measured by diamond stylus profilometer using the following roughness parameters: Ra, Rq, Rz, and Ry. Data were analyzed by one-way ANOVA, Tukey's post hoc and Student-Newman-Keuls post hoc tests. Results: The pH values of the soft drinks ranged from 2.52 (Guarana) to 4.21 (strawberry yoghurt). Orange juice had the highest TA, requiring 5.70 ml of NaOH to reach pH 7.0, whereas Coca-Cola required only 1.87 ml. Roughness parameters indicated that Coca-Cola had the strongest erosion potential during the 15 min of exposure, while Coca-Cola and orange juice were similar during 30- and 60-min exposures. There were no significant differences related to all exposure times between Guarana and Cedevita. Strawberry yoghurt did not erode the enamel surface regardless of the exposure time. Conclusion: All of the tested soft drinks except yoghurt were erosive. Erosion of the enamel surfaces exposed to Coca-Cola, orange juice, Cedevita, and Guarana was directly proportional to the exposure time.
机译:目的:通过测量初始pH和可滴定酸度(TA)来评估各种软饮料的腐蚀性,并使用不同的暴露时间来评估搪瓷的表面粗糙度。材料和方法:使用pH计测量软饮料的初始pH值(组1:可口可乐;组2:橙汁;组3:Cedevita;组4:瓜拉纳,组5:草莓酸奶),以及通过用NaOH滴定来测量TA。牙釉质样本(n = 96)是从人类未磨牙的第三磨牙上切下的,随机分为6组:实验组(1-5组)和对照组(经过滤的唾液)。在10天内,每天3次将样品暴露于50 ml的软饮料中15、30和60分钟,每天3次。浸泡之间,将样品保存在过滤后的唾液中。搪瓷表面粗糙度通过金刚石测针仪使用以下粗糙度参数进行测量:R a ,R q ,R z 和R y 。通过单向方差分析,Tukey事后检验和St​​udent-Newman-Keuls事后检验分析数据。结果:软饮料的pH值范围从2.52(瓜拉纳)到4.21(草莓酸奶)。橙汁的TA最高,需要5.70 ml的NaOH才能达到pH 7.0,而可口可乐只需要1.87 ml。粗糙度参数表明,可口可乐在15分钟的暴露过程中具有最强的腐蚀潜能,而可口可乐和橙汁在30分钟和60分钟的暴露过程中相似。瓜拉纳和Cedevita之间的所有接触时间均无显着差异。不管暴露时间如何,草莓酸奶都不会腐蚀釉质表面。结论:除酸奶外,所有测试的软饮料都具有侵蚀性。暴露于可口可乐,橙汁,Cedevita和瓜拉那的瓷釉表面的侵蚀与暴露时间成正比。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号