首页> 外文期刊>Medical science monitor : >Measurement and comparison of skin dose using OneDose MOSFET and Mobile MOSFET for patients with acute lymphoblastic leukemia
【24h】

Measurement and comparison of skin dose using OneDose MOSFET and Mobile MOSFET for patients with acute lymphoblastic leukemia

机译:使用OneDose MOSFET和移动MOSFET对急性淋巴细胞白血病患者的皮肤剂量进行测量和比较

获取原文

摘要

Background:Total body irradiation is a protocol used to treat acute lymphoblastic leukemia in patients prior to bone marrow transplant. It is involved in the treatment of the whole body using a large radiation field with extended source-skin distance. Therefore measuring and monitoring the skin dose during the treatment is important. Two kinds of metal oxide semiconductor field effect transistor (OneDose MOSFET and mobile MOSEFT) dosimeter are used during the treatment delivery to measure the skin dose to specific points and compare it with the target prescribed dose.The objective of this study was to compare the variation of skin dose in patients with acute lymphatic leukemia (ALL) treated with total body irradiation (TBI) using OneDose MOSFET detectors and Mobile MOSFET, and then compare both results with the target prescribed dose.Material/Methods:The measurements involved 32 patient’s (16 males, 16 females), aged between 14–30 years, with an average age of 22.41 years. One-Dose MOSFET and Mobile MOSFET dosimetry were performed at 10 different anatomical sites on every patient.Results:The results showed there was no variation between skin dose measured with OneDose MOSFET and Mobile MOSFET in all patients. Furthermore, the results showed for every anatomical site selected there was no significant difference in the dose delivered using either OneDose MOSFET detector or Mobile MOSFET as compared to the prescribed dose.Conclusions:The study concludes that One-Dose MOSFET detectors and Mobile MOSFET both give a direct read-out immediately after the treatment; therefore both detectors are suitable options when measuring skin dose for total body irradiation treatment.
机译:背景:全身照射是一种在骨髓移植之前用于治疗急性淋巴细胞白血病的方案。它涉及使用具有扩大的源-皮肤距离的大辐射场对全身进行治疗。因此,在治疗过程中测量和监测皮肤剂量很重要。在治疗过程中使用两种金属氧化物半导体场效应晶体管(OneDose MOSFET和移动式MOSEFT)剂量计测量特定点的皮肤剂量并将其与目标处方剂量进行比较。本研究的目的是比较差异使用OneDose MOSFET检测器和Mobile MOSFET通过全身照射(TBI)治疗的急性淋巴白血病(ALL)患者的皮肤剂量,然后将这两个结果与目标处方剂量进行比较。材料/方法:测量涉及32例患者(16男性,女性16位),年龄在14至30岁之间,平均年龄为22.41岁。在每位患者的10个不同的解剖部位进行一剂量MOSFET和移动MOSFET剂量测定。结果:结果表明,在所有患者中,用OneDose MOSFET和移动MOSFET测量的皮肤剂量之间没有变化。此外,结果显示,对于每个选定的解剖部位,使用OneDose MOSFET检测器或移动MOSFET的剂量与规定剂量相比没有显着差异。结论:研究得出的结论是,单剂量MOSFET检测器和Mobile MOSFET都可以提供治疗后立即直接读出;因此,在测量全身照射治疗的皮肤剂量时,这两种检测器都是合适的选择。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号