首页> 外文期刊>Medical science monitor : >Paraoxonase-1 Enzyme Activity Assay for Clinical Samples: Validation and Correlation Studies
【24h】

Paraoxonase-1 Enzyme Activity Assay for Clinical Samples: Validation and Correlation Studies

机译:临床样品对氧磷酶-1酶活性测定:验证和相关性研究

获取原文
           

摘要

Background Paraoxonase-1 (PON1) enzyme is reported in various types of tissues and linked to numerous pathophysiological disorders. It is a potential biomarker in many pathological conditions such as cardiovascular diseases. Material and Methods We conducted several small-scale studies to evaluate PON1 performance as affected by sample types, storage, and interferences. We also carried out short-term studies to compare the performance of the widely used PON1 assay to the similar commercially available PON1 kit assay method; sample size for the method comparison was N=40, and the number varied for other validation experiments. Results Our studies using various types of anticoagulants show that samples collected in tubes with NaF, citrate, EDTA, clot activator, and sodium heparin have increased PON1 levels that are 49%, 24.5%, 19.8%, 11.4%, and 8%, respectively, higher compared to serum samples collected in plain tubes. However, samples collected in lithium heparin tubes demonstrated 10.4% lower PON1 levels compared to serum collected in plain tubes. Biological interference such as hemolysis has little effect on PON1 levels; however, samples spiked with lipids have shown 13% lower PON 1 levels. Our studies comparing the PON1 method commonly available for PON1 assay and a similar non-ELISA commercially available PON1 kit method showed a weak Spearman correlation coefficient of R2=0.40 for the range of 104.9–245.6 U/L. Conclusions The current study provides new validation data on enzyme PON1 performance. While no appreciable change was seen with storage, samples type affects the enzyme performance. Our results should encourage additional clinical studies to investigate other aspects of factors known to affect PON1 enzyme function and performance.
机译:背景对氧磷酶-1(PON1)酶在各种类型的组织中都有报道,并与许多病理生理疾病有关。在许多病理状况如心血管疾病中,它是潜在的生物标志物。材料和方法我们进行了几次小规模研究,以评估受样品类型,存储和干扰影响的PON1性能。我们还进行了短期研究,以比较广泛使用的PON1测定法与类似的市售PON1试剂盒测定法的性能。方法比较的样本数量为N = 40,其他验证实验的数量有所不同。结果我们使用各种类型的抗凝剂进行的研究表明,在装有NaF,柠檬酸盐,EDTA,凝块活化剂和肝素钠的试管中收集的样品中PON1的水平分别升高了49%,24.5%,19.8%,11.4%和8%。 ,比在普通试管中收集的血清样品要高。然而,与普通管中收集的血清相比,在肝素锂试管中收集的样品显示PON1水平降低了10.4%。诸如溶血等生物干扰对PON1水平影响不大;但是,掺有脂质的样品显示PON 1水平降低了13%。我们的研究比较了通常可用于PON1分析的PON1方法和类似的非ELISA市售PON1试剂盒方法,结果表明,在104.9–245.6 U / L的范围内,Spearman相关系数较弱,R2 = 0.40。结论当前的研究提供了有关酶PON1性能的新验证数据。虽然在储存方面未见明显变化,但样品类型会影响酶的性能。我们的结果应鼓励进行更多的临床研究,以调查已知影响PON1酶功能和性能的因素的其他方面。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号