Comparison of Matrix Frequency-Doubling Technology (FDT) Perimetry with the SWEDISH Interactive Thresholding Algorithm (SITA) Standard Automated Perimetry (SAP) in Mild Glaucoma

机译:轻度青光眼中的矩阵倍频技术(FDT)视野测定法与SWEDISH交互式阈值算法(SITA)标准自动视野测定法(SAP)的比较

获取原文
       

摘要

This study aimed to compare second-generation frequency-doubling technology (FDT) perimetry with standard automated perimetry (SAP) in mild glaucoma. Forty-seven eyes of 47 participants who had mild visual field defect by SAP were included in this study. All participants were examined using SITA 24-2 (SITA-SAP) and matrix 24-2 (Matrix-FDT). The correlations of global indices and the number of defects on pattern deviation (PD) plots were determined. Agreement between two sets regarding the stage of visual field damage was assessed. Pearson’s correlation, intra-cluster comparison, paired t-test, and 95% limit of agreement were calculated using SPSS 24.0. The level of significance was set at P < 0.05. Although there was no significant difference between global indices, the agreement between the two devices regarding the global indices was weak (the limit of agreement for mean deviation was -6.08 to 6.08 and that for pattern standard deviation was -4.42 to 3.42). The agreement between SITA-SAP and Matrix-FDT regarding the Glaucoma Hemifield Test (GHT) and the number of defective points in each quadrant and staging of the visual field damage was also weak. Because the correlation between SITA-SAP and Matrix-FDT regarding global indices, GHT, number of defective points, and stage of the visual field damage in mild glaucoma is weak, Matrix-FDT cannot be used interchangeably with SITA-SAP in the early stages of glaucoma.
机译:这项研究旨在比较轻度青光眼中的第二代倍频技术(FDT)和标准自动视野(SAP)。本研究纳入了47名SAP轻度视野缺损参与者的47只眼睛。使用SITA 24-2(SITA-SAP)和矩阵24-2(Matrix-FDT)对所有参与者进行了检查。确定了全局指数与图案偏差(PD)图上缺陷数量的相关性。评估两组在视野损害阶段之间的一致性。使用SPSS 24.0计算了Pearson的相关性,群内比较,配对t检验和95%的同意限。显着性水平设定为P <0.05。尽管全局指数之间没有显着差异,但是两个设备之间关于全局指数的一致性很弱(平均偏差的一致性极限为-6.08至6.08,模式标准偏差的一致性极限为-4.42至3.42)。 SITA-SAP和Matrix-FDT之间关于青光眼半场试验(GHT)以及每个象限中的缺陷点数量以及视野损害分级的协议也很薄弱。由于SITA-SAP和Matrix-FDT在总体指标,GHT,缺陷点数和视野损害阶段在轻度青光眼之间的相关性较弱,因此Matrix-FDT不能在早期与SITA-SAP互换使用青光眼。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号