首页> 外文期刊>Materiales de Construccion >Modification of strut effectiveness factor for reinforced concrete deep beams strengthened with CFRP laminates
【24h】

Modification of strut effectiveness factor for reinforced concrete deep beams strengthened with CFRP laminates

机译:CFRP层板加固钢筋混凝土深梁的支撑系数的修正。

获取原文
   

获取外文期刊封面封底 >>

       

摘要

This paper proposes a method to modify the strut effectiveness factor in the strut-and-tie model for CFRP-strengthened reinforced concrete deep beams. Two groups of deep beams comprising six ordinary reinforced concrete deep beams and six CFRP-strengthened reinforced concrete deep beams were experimentally tested under the four-point bending configuration. The shear span-to-effective depth ratio of the beams in each group was 0.75, 1.00, 1.25, 1.50, 1.75, and 2.00. The theoretical principal tensile strain in CFRP-strengthened struts was modified based on a proposed empirical relationship, based on two ratios: the experimental to the theoretical value of principal tensile strain and the shear span-to-effective depth of deep beams.
机译:本文提出了一种在CFRP加固钢筋混凝土深梁的拉杆模型中改变拉杆有效系数的方法。在四点弯曲构型下,对包括6条普通钢筋混凝土深梁和6条CFRP加固钢筋混凝土深梁的两组深梁进行了试验测试。每组中梁的剪切跨度与有效深度之比为0.75、1.00、1.25、1.50、1.75和2.00。基于建议的经验关系,基于以下两个比率修改了CFRP加固支杆中的理论主拉伸应变:主拉伸理论值的实验值和深梁的剪切跨度到有效深度。