首页> 外文期刊>Frontiers in Oncology >Assessment of Geant4 Prompt-Gamma Emission Yields in the Context of Proton Therapy Monitoring
【24h】

Assessment of Geant4 Prompt-Gamma Emission Yields in the Context of Proton Therapy Monitoring

机译:在质子治疗监测的背景下评估Geant4即时Gamma发射量

获取原文
           

摘要

Monte Carlo tools have been long used to assist the research and development of solutions for proton therapy monitoring. The present work focuses on the prompt-gamma emission yields by comparing experimental data with the outcomes of the current version of Geant4 using all applicable proton inelastic models. For the case in study and using the binary cascade model, it was found that Geant4 overestimates the prompt-gamma emission yields by 40.2?±?0.3%, even though it predicts the prompt-gamma profile length of the experimental profile accurately. In addition, the default implementations of all proton inelastic models show an overestimation in the number of prompt gammas emitted. Finally, a set of built-in options and physically sound Geant4 source code changes have been tested in order to try to improve the discrepancy observed. A satisfactory agreement was found when using the QMD model with a wave packet width equal to 1.3?fm~(2).
机译:长期以来,蒙特卡洛工具一直用于协助质子治疗监测解决方案的研究和开发。通过使用所有适用的质子非弹性模型将实验数据与当前版本的Geant4的结果进行比较,本工作着重于瞬发伽马发射。对于正在研究的情况并使用二元级联模型,发现Geant4高估了即时伽马发射的产量40.2?±?0.3%,即使它准确地预测了实验剖面的即时伽马剖面长度。此外,所有质子非弹性模型的默认实现都显示出所发射的即时伽马数量过高。最后,已经测试了一组内置选项和物理上合理的Geant4源代码更改,以尝试改善观察到的差异。当使用QMD模型的波包宽度等于1.3?fm〜(2)时,发现了令人满意的协议。