Intra- and inter-examiner reliability of the head postural assessment by computerized photogrammetry

机译:计算机摄影测量法对头部姿势评估的内部和内部检查者可靠性

获取原文
       

摘要

Scientific articles about reliability of photogrammetry for cervical spine posture evaluation are infrequent. The aim of the present investigation is to verify intra- and inter-examiner reliability of computerized photogrammetry method for head postural evaluation in lateral view. Twenty-five young women between 20 and 30 years old were positioned seated in an upright position and photographed in lateral view. The photographs were imported to Corel Draw X13 program for postural evaluation by computerized photogrammetry. The reliability of intra- and inter-examiner analyses were performed for the angles: condyle-acromion (ACA), menton-sternum (AME) and Frankfurt (AF). The photogrammetry was performed by two examiners: EA and EB. The EA performed analysis of the photos of participants twice (A1 and A2) for the same angles in a range of three months to assess intra-examiner reliability. The EB performed the photogrammetry for the same angles (B1) for comparison with the data from EA (inter-examiner analysis). Excellent correlation in the intra-examiner analysis (A1 and A2) was found for the angles: ACA and AME, both with a 1.0 interclass correlation coefficient (ICC); for the AF angle, it was found ICC=0.78. For the ICC inter-examiner between A1 and B1, it was observed: ACA (ICC=0.24), AME (ICC=0.26), and AF (ICC=0.00). For the comparison between A2 and B1 the ICC values were: 0.23; 0.27; and 0.00, respectively for ACA, AME and AF, classified as weak correlations. The photogrammetry is reliable when performed by the same examiner. The inter-examiner assess showed low reliability, what could have been compromised by the reduced experience of the EB in applying the method.
机译:关于用于颈椎姿势评估的摄影测量学的可靠性的科学文章很少。本研究的目的是验证用于侧视头部姿势评估的计算机摄影测量方法的内部和内部检查者可靠性。 25名20至30岁的年轻妇女坐在直立位置,并在侧面拍摄照片。将照片导入到Corel Draw X13程序中,以通过计算机摄影测量法进行姿势评估。检查者和检查者之间的分析的可靠性是针对以下角度进行的:con突(ACA),芒通胸骨(AME)和法兰克福(AF)。摄影测量由两名检查员进行:EA和EB。 EA在三个月的时间内两次对相同角度的参与者的照片(A1和A2)进行了分析,以评估考官内部的可靠性。 EB对相同角度(B1)进行摄影测量,以与EA的数据进行比较(内部检查者分析)。在检查者内部分析(A1和A2)中发现以下角度具有极好的相关性:ACA和AME角度均具有1.0的类间相关系数(ICC);对于AF角,发现ICC = 0.78。对于A1和B1之间的ICC审查员,观察到:ACA(ICC = 0.24),AME(ICC = 0.26)和AF(ICC = 0.00)。为了比较A2和B1,ICC值为:0.23; 0.27;和ACA,AME和AF分别为0.00和0.00,归为弱相关。由同一位检查员进行摄影测量是可靠的。审查员之间的评估显示出较低的可靠性,这可能是由于采用该方法而导致的EB经验减少所致。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号