首页> 外文期刊>Electrification of transport >Results of continuous wireless mode changes on experimental sections of the changed current of the Lviv railway
【24h】

Results of continuous wireless mode changes on experimental sections of the changed current of the Lviv railway

机译:利沃夫铁路变化电流实验段上连续无线模式变化的结果

获取原文
   

获取外文期刊封面封底 >>

       

摘要

The article presents the results of the work on the evaluation of the wear of the contact wire in the areas of alternating current during the operation of the electromotive force equipped with different types of contact lining pantograph. The authors found that prior to the beginning of the experiment there was an exceeding of the standard for wear of the contact wire in 1,37 times. During the course of the work in circulation at the experimental site there were about 30% of the electromotive structure equipped with strips of pantographs from the material "Romanite-UHFL". This made it possible to create a protective conductive film and, as a result, to significantly reduce the wear of the contact wire.
机译:该文章介绍了在配备不同类型的接触衬套受电弓的电动势运行过程中,评估交流区域中接触线磨损的工作结果。作者发现,在实验开始之前,接触线的磨损标准超过了1.37倍。在实验现场的循环工作过程中,约有30%的电动结构装有“ Romanite-UHFL”材料制成的受电弓条。这使得可以形成保护性导电膜,并且因此可以显着减少接触线的磨损。