首页> 外文期刊>European Radiology Experimental >Imaging features in post-mortem x-ray dark-field chest radiographs and correlation with conventional x-ray and CT
【24h】

Imaging features in post-mortem x-ray dark-field chest radiographs and correlation with conventional x-ray and CT

机译:验尸X射线暗场胸部X光片的成像特征以及与常规X射线和CT的相关性

获取原文
           

摘要

Abstract BackgroundAlthough x-ray dark-field imaging has been intensively investigated for lung imaging in different animal models, there is very limited data about imaging features in the human lungs. Therefore, in this work, a reader study on nine post-mortem human chest x-ray dark-field radiographs was performed to evaluate dark-field signal strength in the lungs, intraobserver and interobserver agreement, and image quality and to correlate with findings of conventional x-ray and CT.MethodsIn this prospective work, chest x-ray dark-field radiography with a tube voltage of 70?kVp was performed post-mortem on nine humans (3 females, 6 males, age range 52–88?years). Visual quantification of dark-field and transmission signals in the lungs was performed by three radiologists. Results were compared to findings on conventional x-rays and 256-slice computed tomography. Image quality was evaluated. For ordinal data, median, range, and dot plots with medians and 95% confidence intervals are presented; intraobserver and interobserver agreement were determined using weighted Cohen κ .ResultsDark-field signal grading showed significant differences between upper and middle ( p =?0.004–0.016, readers 1–3) as well as upper and lower zones ( p =?0.004–0.016, readers 1–2). Median transmission grading was indifferent between all lung regions. Intraobserver and interobserver agreements were substantial to almost perfect for grading of both dark-field ( κ =?0.793–0.971 and κ =?0.828–0.893) and transmission images ( κ =?0.790–0.918 and κ =?0.700–0.772). Pulmonary infiltrates correlated with areas of reduced dark-field signal. Image quality was rated good for dark-field images.ConclusionsChest x-ray dark-field images provide information of the lungs complementary to conventional x-ray and allow reliable visual quantification of dark-field signal strength.
机译:尽管在不同动物模型中对X射线暗场成像进行了广泛的肺成像研究,但是关于人肺成像特征的数据非常有限。因此,在这项工作中,对9个验尸后的人类胸部X射线暗场X射线照片进行了读者研究,以评估肺部的暗场信号强度,观察者之间和观察者之间的一致性以及图像质量,并将其与在这项前瞻性工作中,对9名人类(3名女性,6名男性,年龄范围52-88岁)进行了尸体解剖,其管电压为70?kVp的胸部X射线暗场射线照相)。肺部暗场和透射信号的视觉量化由三位放射科医生完成。将结果与常规X射线和256层计算机断层扫描的结果进行比较。评价图像质量。对于序数数据,显示了具有中位数和95%置信区间的中位数,范围和点图;使用加权Cohenκ确定观察者内部和观察者之间的一致性。结果暗场信号分级显示上部和下部(p =?0.004-0.016,阅读器1-3)以及上部和下部区域(p =?0.004-0.016)之间存在显着差异。 ,读者1-2)。所有肺区域之间的中位传输等级无关。观察者内部和观察者之间的协议对于暗场(κ=?0.793-0.971和κ=?0.828-0.893)和透射图像(κ=?0.790-0.918和κ=?0.700-0.772)的分级是基本至几乎完美的。肺浸润与暗场信号减少的区域相关。图像质量在暗场图像中被评为良好。结论胸部X射线暗场图像可提供与常规X射线互补的肺部信息,并可以对暗场信号强度进行可靠的视觉量化。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号