ObjectiveReal-time continuous glucose monitoring (RT-CGM) provides detailed information on glucose patterns and trends, thus allowing the patients to manage their diabetes more effectively.DesignThe aim of this study was to explore the potential beneficial effects of the use of RT-CGM on diabetes management compared with self blood glucose measurement (SBGM) in patients with type 1 diabetes mellitus (T1DM), by means of a systematic review and meta-analysis of randomized controlled trials (RCTs).MethodsMEDLINE, EMBASE, and the Cochrane Library were searched through by two independent investigators for RCTs concerning the use of RT-CGM in patients with T1DM. Only studies with a similar insulin regimen in the experimental and control groups were included in the analysis.ResultsSeven RCTs ( n =948) met the inclusion criteria. Combined data from all studies showed better HbA1c reduction in subjects using RT-CGM compared with those using SBGM (mean difference (MD) ?0.25; 95% confidence interval (95% CI): from ?0.34 to ?0.17; P <0.001). Patients treated with insulin pump and RT-CGM had a lower HbA1c level compared with subjects managed with insulin pump and SBGM (four RCTs, n =497; MD ?0.26; 95% CI: from ?0.43 to ?0.10; P =0.002). The benefits of applying RT-CGM were not associated with an increasing rate of major hypoglycemic episodes. The use of RT-CGM for over 60–70% of time was associated with a significant lowering of HbA1c.ConclusionsRT-CGM is more beneficial than SBGM in reducing HbA1c in patients with type 1 diabetes. Further studies are needed to evaluate the efficacy of this system in the pediatric population, especially in very young children.
机译:目的实时连续血糖监测(RT-CGM)提供有关血糖模式和趋势的详细信息,从而使患者能够更有效地控制糖尿病。设计本研究旨在探讨使用RT-CGM的潜在益处通过对随机对照试验(RCT)进行系统回顾和荟萃分析,对1型糖尿病(T1DM)患者的糖尿病管理与自身血糖测量(SBGM)进行比较。方法MEDLINE,EMBASE和Cochrane库由两名独立的研究者搜索了有关在T1DM患者中使用RT-CGM的RCT。分析仅包括实验组和对照组中采用相似胰岛素治疗方案的研究。结果有7个RCT(n = 948)符合纳入标准。来自所有研究的综合数据显示,与使用SBGM的受试者相比,使用RT-CGM的受试者的HbA1c降低效果更好(平均差(MD)≤0.25; 95%可信区间(95%CI):从0.34到0.17; P <0.001) 。与接受胰岛素泵和SBGM治疗的受试者相比,接受胰岛素泵和RT-CGM治疗的患者的HbA1c水平较低(四个RCT,n = 497; MD = 0.26; 95%CI:从0.43至0.10; P = 0.002) 。应用RT-CGM的好处与主要降血糖事件的发生率增加无关。 RT-CGM的使用时间超过60-70%与HbA1c的显着降低有关。结论RT-CGM在降低1型糖尿病患者的HbA1c方面比SBGM更为有益。需要进一步的研究来评估该系统在儿科人群中的疗效,尤其是对于年幼的儿童。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号