...
首页> 外文期刊>Italian Journal of Public Health >The use of fractal dimension methods in clinical epidemiology: an application for postural assessment
【24h】

The use of fractal dimension methods in clinical epidemiology: an application for postural assessment

机译:分形维数在临床流行病学中的应用:姿势评估的应用

获取原文
           

摘要

Background: this study considers the analysis of postural sway by comparing the use of a fractal dimension outcome (DBOX) with the usual sway ellipse area (SEA), calculated by the least squares method. Both the response variables come from centre of pressure (COP) dynamics detected by means of a force platform. Methods: recent literature regarding postural stability assessment in subjects with muscularskeletal disorders, or neuromuscular diseases affecting their motor skills, has suggested, both for practical and theoretical reasons, the use of some fractal dimension as a good outcome measurement for overall postural status. A sample group of 24 male subjects was recruited. The postural stabilogram was recorded both with eyes open (EO) and eyes closed (EC) while standing upright. A matched-pair comparison of the sway ellipse area with the COP dynamics box counting dimension was performed. A ROC analysis of the outcome variables was performed. Then, a ROC comparison of the tests, using the area under the curve (AUC) index, was conducted. Results: the comparison of paired groups showed a statistically significant difference between EO and EC status, according to the sway ellipse area and the fractal dimension (p<0.05). The ROC analysis, describing the test performance in terms of AUC difference, was statistically significant (p<0.05). The comparison of the AUCs showed an overall superior performance of the DBOX with respect to SEA (p<0.05). Conclusions: this study showed a statistically significant better overall performance of DBOX with respect to SEA, suggesting possible improvements of clinical practice, as well as theoretical insights into the response patterns.
机译:背景:本研究通过将分形维数结果(DBOX)与通过最小二乘法计算的通常的摇摆椭圆面积(SEA)进行比较,来考虑姿势摇摆的分析。这两个响应变量均来自通过力平台检测到的压力中心(COP)动态。方法:关于实用性和理论上的原因,有关肌肉骨骼疾病或影响其运动技能的神经肌肉疾病患者的姿势稳定性评估的最新文献表明,使用某些分形维数作为总体姿势状态的良好结局指标。招募了一个由24名男性受试者组成的样本组。直立站立时睁眼(EO)和闭眼(EC)记录姿势稳定图。将摇摆椭圆区域与COP动态框计数尺寸进行配对比较。对结果变量进行了ROC分析。然后,使用曲线下面积(AUC)指数进行了测试的ROC比较。结果:配对组的比较显示,根据摇摆椭圆面积和分形维数,EO和EC状态之间存在统计学差异(p <0.05)。用AUC差异描述测试性能的ROC分析具有统计学意义(p <0.05)。 AUC的比较显示DBOX相对于SEA总体上具有优越的性能(p <0.05)。结论:这项研究显示出DBOX相对于SEA的总体性能具有统计学上的显着提高,表明临床实践可能得到改善,以及对反应模式的理论见解。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号