首页> 外文期刊>International Journal of Women s Health >Acoustic radiation force impulse imaging with Virtual Touch? tissue quantification: mean shear wave velocity of malignant and benign breast masses
【24h】

Acoustic radiation force impulse imaging with Virtual Touch? tissue quantification: mean shear wave velocity of malignant and benign breast masses

机译:使用Virtual Touch进行声辐射力脉冲成像?组织定量:恶性和良性乳腺肿块的平均剪切波速度

获取原文

摘要

Abstract: Acoustic radiation force impulse imaging (ARFI) with Virtual Touch? tissue quantification (VTTQ) enables the determination of shear wave velocity (SWV) in meters per second (m/s). The aim of our study was to describe the mean SWV in normal breast tissue and various breast masses. We performed measurements of SWV with ARFI VTTQ in 145 breast masses (57 malignant, 88 benign) and in the adjacent breast parenchyma and adipose tissue. The mean SWV as well as the rate of successful measurements were analyzed. The difference between adipose tissue and parenchyma was statistically significant (3.05 versus 3.65 m/s) (P < 0.001). Focusing on breast masses, numerous measurements exceeded the upper limit of possible measurement (≥9.10 m/s, indicated as "X.XX m/s"). Nevertheless, the difference between the malignant and benign masses was statistically significant (8.38 ± 1.99 m/s versus 5.39 ± 2.95 m/s) (P < 0.001). The best diagnostic accuracy (75.9%) was achieved when the cutoff point for malignancy was set to 9.10 m/s in ARFI VTTQ. This implies that the SWV was regarded as suspicious when the upper limit of possible measurement was exceeded and the machine returned the value X.XX m/s. In conclusion, ARFI VTTQ is a feasible method for measurement of SWV in a region of interest. Furthermore, we propose the event of a highly elevated SWV as a significant criterion for malignancy. However, the method is technically not yet fully developed, and the problem of unsuccessful measurements must still be solved.
机译:摘要:带有Virtual Touch的声辐射力脉冲成像(ARFI)?组织量化(VTTQ)可以确定以米/秒(m / s)为单位的剪切波速度(SWV)。我们研究的目的是描述正常乳腺组织和各种乳腺肿块中的平均SWV。我们用ARFI VTTQ对145个乳腺肿块(57个恶性,88个良性)以及邻近的乳腺实质和脂肪组织进行了SWV测量。分析了平均SWV以及成功测量的速率。脂肪组织和实质之间的差异具有统计学意义(3.05对3.65 m / s)(P <0.001)。针对乳房肿块,许多测量结果超出了可能测量的上限(≥9.10 m / s,显示为“ X.XX m / s”)。然而,恶性肿块与良性肿块之间的差异具有统计学意义(8.38±1.99 m / s与5.39±2.95 m / s)(P <0.001)。当在ARFI VTTQ中将恶性截止点设置为9.10 m / s时,可达到最佳诊断准确性(75.9%)。这意味着当超过可能测量的上限并且机器返回值X.XX m / s时,SWV被视为可疑。总之,ARFI VTTQ是测量感兴趣区域中SWV的可行方法。此外,我们建议将SWV高度升高作为恶性肿瘤的重要标准。然而,该方法在技术上尚未完全开发,并且仍然必须解决测量不成功的问题。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号