This field investigation ofthermal comfort parameters in Green Building Index (GBI)-rated office buildingsemploying various fa?ade-shading devices compared thermal performance in termsof four main variables: indoor air temperature, indoor relative humidity, meanradiant temperature, and indoor air velocity. Over five days of fieldwork ateach building, the four variables of interest were measured, recorded, andanalysed using Excel graphs. The results show that the thermal comfortperformance of each building was acceptable within the parameters of the GBINon-Residential New Construction (NRNC) Tools for Indoor Environmental Quality(IEQ). In general, observed values were good for three of the four thermalparameters: indoor air temperature, indoor relative humidity and mean radianttemperature. However, indoor air velocity fell below the acceptable range asdefined by the GBI NRNC Tools. One possible reason for this negative outcome islow air exchange from the air conditioning systems in the selected buildings.??
机译:这项对采用各种立面遮阳设备的绿色建筑指数(GBI)等级的办公楼中的热舒适参数的现场调查从四个主要变量方面比较了热性能:室内空气温度,室内相对湿度,平均辐射温度和室内空气速度。在每个建筑物的为期五天的实地调查中,使用Excel图形对四个感兴趣的变量进行了测量,记录和分析。结果表明,在GBINon住宅新建筑(NRNC)室内环境质量(IEQ)工具的参数范围内,每栋建筑物的热舒适性能均可接受。通常,对于四个热参数中的三个,观测值是好的:室内空气温度,室内相对湿度和平均辐射温度。但是,室内风速低于GBI NRNC工具定义的可接受范围。这种负面结果的一个可能原因是所选建筑物中空调系统的空气交换不足。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号