Objective: The use of the classical approach of analytical validation, in practice or in the literature, is common. However, statistical verification, that looks separately the two errors (such as bias and precision) to make a decision, presents a risk to declare that an analytical method is valid while it is not, or?conversely. To minimize this risk, a new approach based on the concept of total error was proposed. Methods : This approach proposes a calculation the two sided tolerance interval by combining the two errors; bias and precision, in order to examine the validity of an analytical and bioanalytical method at each concentration level. In this paper, we aim to demonstrate the applicability and simplicity of the both methods based on the total error approach: accuracy profile and uncertainty profile. This study will be illustrated by validation case of a spectrophotometric method for the determination of trace amounts of acetaminophen in human plasma. Results : After the introduction of the correction coefficient which is worth 1.16, the results obtained with accuracy profile approach show clearly that the bioanalytical method is valid over a concentrations range of [100.34- 500] μg mL -1 since the upper and lower 90%-expectation tolerance limits have fallen within the two acceptance limits of ± 20%. The same results found using the uncertainty profile approach because the "two - sided 66.7%-content, 90% -confidence tolerance intervals "are found within two acceptance limits of ± 20% over the range of [170; 500] μm mL -1 . Conclusion: The excellence of the total error approach was showen since it enables successfully to validate the analytical procedure as well the calculation of the measurement uncertainty at each concentration level. Keywords: Error total, Analytical validation, Uncertainty profile, Accuracy profile, Measurement uncertainty, Bioanalytical method.
机译:目的:在实践中或文献中普遍使用经典的分析验证方法。但是,将两个错误(例如偏差和精度)分开看做决策的统计验证存在风险,即宣称一种分析方法有效,反之则无效。为了使这种风险最小化,提出了一种基于总误差概念的新方法。方法:该方法提出了通过结合两个误差来计算两侧公差区间的方法。偏差和精确度,以检验每种浓度水平下分析和生物分析方法的有效性。在本文中,我们旨在证明基于总误差方法的两种方法的适用性和简便性:准确性曲线和不确定性曲线。分光光度法测定人血浆中对乙酰氨基酚含量的验证案例将说明这一研究。结果:在引入了1.16的校正系数后,使用精度分布图方法获得的结果清楚地表明,由于上限和下限90%,该生物分析方法在[100.34- 500]μgmL -1的浓度范围内是有效的-预期公差极限已落在±20%的两个接受极限之内。使用不确定度分布图方法也发现了相同的结果,因为在[170;范围内,在±20%的两个接受范围内发现了“双面66.7%含量,90%-置信公差区间”。 500]μmmL -1。结论:由于总误差法能够成功地验证分析程序以及计算每个浓度水平下的测量不确定度,因此显示出卓越的总误差法。关键字:总误差,分析验证,不确定度分布,准确度分布,测量不确定度,生物分析方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号