...
首页> 外文期刊>International Journal of TROPICAL DISEASE & Health >Clinical Study of Trans-catheter Closure of Patent Ductus Arteriosus with Occluder Devices among Children Aged 9 Months to 18 Years
【24h】

Clinical Study of Trans-catheter Closure of Patent Ductus Arteriosus with Occluder Devices among Children Aged 9 Months to 18 Years

机译:9个月至18岁儿童经封堵器封堵动脉导管未闭的临床研究

获取原文
   

获取外文期刊封面封底 >>

       

摘要

Background and Objectives: This study was aimed at determining our experience with occluder devices over last 5 years. The objective of this study is to compare the complication rates and efficacy of different devices used for the closure of PDA. Methods: A cross-sectional retrospective study in which a review of the records of all children who had PDA surgery in a paediatric cardiac center, Innova Childrens’ Heart Hospital, Hyderabad, India over a five year period (June 2007 and July 2011) was undertaken. The hospital records showed that from June 2007 to July 2011, a total of 456 children aged 9 months to 18 years had trans-catheter closure over the study period, of these, 159 underwent trans-catheter device closure of PDA. A team of experienced paediatric cardiologist performed all the procedures. Results: Out of the 159 cases, 134 (84.2%) were successful while 25 (15.7%) were complicated. Five (5) {20.0%} cases had temporary residual leak, 3 (12.0%) had failure of the procedure that required surgical intervention, 9 (36.0%) had protrusion of the device into the aorta without significant Doppler pressure gradient. There exist a relation between success, complication and device used for the procedure.The type of occluder device used for the procedure significantly affect the outcome (χ2 = 16.37; p = 0.02) Chinese occlude devise had the highest success rate. Twenty five (25.0) {15.7%} patients had complications in all. The commonest complication (protrusion of the device into the aorta) was seen in 3 (1.8%) cases with Chinese duct occluder, 3(1.8%) with Sear Heart R and 3 (1.8%) cases with ADOs. Non died from the procedure. Conclusion: The commonest complication is (protrusion of the device into the aorta) with Chinese occludes devise showing the highest success rate. The learning curve and accumulating experience play an indispensable role in choosing the proper device and its size.
机译:背景与目的:本研究旨在确定我们过去5年使用封堵器的经验。这项研究的目的是比较用于闭合PDA的不同器械的并发症发生率和疗效。方法:一项横断面回顾性研究,回顾了印度海德拉巴Innova儿童心脏医院的小儿心脏中心在五年内(2007年6月和2011年7月)进行过PDA手术的所有儿童的记录。承担。医院记录显示,从2007年6月至2011年7月,共有456名9个月至18岁的儿童在研究期间关闭了经导管,其中159例接受了PDA的经导管器械封闭。一组经验丰富的儿科心脏病专家完成了所有程序。结果:159例中成功134例(84.2%),而25例(15.7%)复杂。五(5){20.0%}例患者存在暂时性残余渗漏,3例(12.0%)因需要外科手术而无法手术,9例(36.0%)具无明显多普勒压力梯度而伸入主动脉。成功,复杂程度与用于手术的器械之间存在关系。用于手术的封堵器装置的类型会显着影响结果(χ 2 = 16.37; p = 0.02)。成功率最高。二十五(25.0){15.7%}患者共有并发症。在中国导管封堵器中,最常见的并发症(装置伸入主动脉)见3例(1.8%),Sear Heart R 见3例(1.8%),与Sear Heart R 见3例(1.8%)。 ADOs。非死于手术。结论:最常见的并发症是(装置伸入主动脉),中国人的闭塞装置显示出最高的成功率。学习曲线和积累的经验在选择合适的设备及其尺寸方面起着不可或缺的作用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号