This paper describes the investigation being performed by the Laboratory of Fluid Mechanics and Energy (LFME) in order to test the performance of heat pipes as capillary pumps. This investigation is part of the EU funded research project TRI-GEN EGD that aims in the development of a novel Tri-generation Electrogasdynamic converter system. The capillary pump will be used to pump the working fluid of the system using external waste heat. Furthermore, since the capillary pump has no moving parts it will provide the system with greater reliability. To this end, a Capillary Pumped Loop (CPL) experimental setup was designed and constructed by LFME. A CPL is a closed loop system that pumps liquid by passive means, based on the operating principles of heat pipes. Specifically capillary forces are generated on a porous structure that exists in the evaporation section and is responsible for pushing the working fluid from a high temperature source to a low temperature sink. In this paper the experimental setup constructed as well as the experimental procedure followed are described and preliminary results are presented.
机译:本文介绍了由流体力学和能源实验室(LFME)进行的研究,目的是测试热管作为毛细管泵的性能。这项调查是欧盟资助的研究项目TRI-GEN EGD的一部分,该项目旨在开发新型的第三代电气转换系统。毛细管泵将用于利用外部废热泵送系统的工作流体。此外,由于毛细管泵没有运动部件,它将为系统提供更高的可靠性。为此,LFME设计并构建了毛细管泵送回路(CPL)实验装置。 CPL是基于热管的工作原理通过被动方式泵送液体的闭环系统。具体地,在蒸发部分中存在的多孔结构上产生毛细管力,该毛细管力负责将工作流体从高温源推向低温阱。在本文中,描述了构建的实验装置以及遵循的实验程序,并给出了初步结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号