Validity of Arm-to-Arm BIA Devices Compared to DXA for Estimating %fat in College Men and Women

机译:手臂到手臂的BIA设备与DXA相比在估计男女大学生脂肪百分比方面的有效性

获取原文
获取外文期刊封面目录资料

摘要

International Journal of Exercise Science 10(7): 977-988, 2017. Bioelectric impedance analysis (BIA) devices are commonly used to estimate percent body fat (%fat), although validation of their accuracy varies widely. The purpose of this study was to assess the validity of four commonly used BIA devices compared to dual-energy X-ray absorptiometry (DXA). College-aged men (n = 29, age = 19.7 ± 1.2 y, weight = 76.9 ± 12.5 kg) and women (n = 31, age = 20.5 ± 0.8 y, weight = 61.5 ± 9.2 kg) were evaluated for %fat using four single-frequency (50 mHz) BIA devices and DXA. A gender x device repeated measures ANOVA indicated some less expensive BIA devices produced %fat values that were not significantly different from DXA. A thumb-to-thumb BIA device produced the closest values in men (21.9 ± 6.6%) and women (32.1 ± 5.3%) compared to DXA (20.6 ± 6.1% and 30.3 ± 5.4%, respectively). The two more expensive BIA devices significantly underestimated in men (14.7 ± 5.8% and 17.0 ± 5.6%) and women (23.3 ± 4.2% and 23.3 ± 4.2%) compared to DXA. Interclass correlation coefficients with DXA were higher for the more expensive devices in men (ICC = 0.899 and 0.958) than the less expensive devices (ICC = 0.681 and 0.730). In women, all BIA devices showed moderate correlations with DXA (ICC = 0.537 to 0.658). Despite the convenience of simple BIA devices, their use in estimating body composition in young men and women might be questionable due to large variations in the differences between DXA and each device in this study
机译:International Journal of Exercise Science 10(7):977-988,2017。生物电阻抗分析(BIA)设备通常用于估算人体脂肪百分比(%fat),尽管其准确性的验证差异很大。这项研究的目的是评估与双能X射线吸收仪(DXA)相比,四种常用BIA设备的有效性。使用以下方法评估大学肥胖的男性(n = 29,年龄= 19.7±1.2 y,体重= 76.9±12.5 kg)和女性(n = 31,年龄= 20.5±0.8 y,体重= 61.5±9.2 kg)。四个单频(50 mHz)BIA设备和DXA。性别x装置重复测量的方差分析(ANOVA)表明,一些较便宜的BIA装置产生的脂肪百分比与DXA并无显着差异。与DXA(分别为20.6±6.1%和30.3±5.4%)相比,拇指到拇指BIA装置产生的数值最接近男性(21.9±6.6%)和女性(32.1±5.3%)。与DXA相比,男性(14.7±5.8%和17.0±5.6%)和女性(23.3±4.2%和23.3±4.2%)两种价格昂贵的BIA设备明显低估了。与价格较便宜的设备(ICC = 0.681和0.730)相比,价格较高的男性设备(ICC = 0.899和0.958)与DXA的类间相关系数更高。在女性中,所有BIA装置均与DXA呈中度相关(ICC = 0.537至0.658)。尽管简单的BIA设备方便,但由于本研究中DXA与每种设备之间的差异存在很大差异,因此它们在估计年轻人的身体成分中的使用可能会受到质疑。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号